D V P - E S 2 / E X 2 / S S 2 / S A2 / S X 2 O p e r a t i o n M a n u a l - P r o g r a m m i n g

3 - 4 2 4

API Mnemonic

Operands

Function

191

D PPMR

2-Axis Relative Point to

Point Motion

Controllers

ES2/EX2 SS2 SA2

SE

SX2

Bit Devices

Word devices

Program Steps

Type

OP

X Y M S

K H

KnX

KnY KnM KnS T C D E F

S

1

* *

*

S

2

* *

*

S

* *

*

D

*

DPPMR: 17 steps

PULSE 16-bit 32-bit

ES2/EX2 SS2

SA2

SE

SX2 ES2/EX2 SS2

SA2

SE

SX2 ES2/EX2 SS2

SA2

SE

SX2

Operands:

S

1

: Number of output pulses on X axis S

2

: Number of output pulses on Y axis S: Max. point to

point output frequency D: Pulse output device

Explanations:

1.

For ES2/EX2 models, only V1.20 or above supports the function.

2.

The instruction only supports the pulse output type: Pulse / Direction.

3.

S

1

and S

2

specify the number of output pulses (relative positioning) on X axis (Y0) and Y axis

(Y2). Range: -2,147,483,648 ~ +2,147,483,647 (The “+/-“ sign indicates the forward/backward

direction). In forward direction, the

present value of pulse output on CH0 (D1031 High, D1030

low), CH1 (D1337 high, D1336 low) increases. In reverse direction pulse output, value in

(D1031, D1330) and (D1336, D1337) decreases.

4.

S: If the max output frequency is smaller than 100Hz, the output will be operated at 100Hz. If

the setting is bigger than 100kHz, the output will be operated at 100kHz

5.

D can designate Y0 only.

Y0 is the pulse output point of X axis;

Y1 is the direction signal output of X axis.(OFF: positive; ON: negative)

Y2 is the pulse output point of Y axis;

Y3 is the direction signal output of Y axis (OFF: positive; ON: negative)

When the pulse output is completed, the direction output signal will not be OFF unless the

drive contact is OFF.

6.

D1340 is start/end frequency setting of X/Y axis. When the set value is smaller than 6Hz, PLC

will take 6 Hz as the set value. D1343 is the ramp up/down time setting of X/Y axis. If the ramp

up/down time is shorter than 20ms, the frequency will be operated at 20ms. Default: 100ms.

7.

When PPMR instruction is enabled, the start frequency and acceleration/deceleration time in Y

axis will be the same as the settings in X axis. In addition, setting ramp-down time individually

by D1348/D1349 is not recommended because it could lead to the inconsistency between X

and Y axes. Also, the flags of “pulse output pause (immediate)” are not applicable. To stop the

pulse output, simply turn off the drive contact of this instruction.