Delta DVP-ES2 User Manual
Page 67
2 . P r o g r a m m i n g C o n c e p ts
Applicable Hardware High Speed Counters:
1-phase
input
1-phase 2-input
2-phase 2-input
C
X
C243 C244 C245 C246 C247 C248 C249 C250 C251 C252 C253 C254
X0 U
U/D
U/D
U
U A
A
X1 R
Dir
Dir
D
D B
B
X2 U
U/D
U/D
A
A
X3 R
Dir
Dir
B
B
X4
R R R
X5
R
R
U: Count up
A: Phase A input
Dir: Directoin signal input
D: Count down
B: Phase B input
R:
Reset signal input
Note:
1.
The max frequency of the 1-phase input counters X0 (C243) and X2(C244) is 100kHz on
ES2/EX2/SA2/SX2 model and 20kHz on SS2 model.
2.
The max frequency of the 1-phase 2-input counters (X0, X1)(C245, C246) and (X2, X3)(C249,
C250) is 100kHz on ES2/EX2/SA2/SX2 model and 20kHz on SS2 model.
3.
The max frequency of the 1-phase 2-input counters (X0, X1)(C247, C248) is 10kHz on
ES2/EX2/SS2/SX2 model and 100kHz on 32ES211T and SA2 model..
4.
The max frequency of the 2-phase 2-input counter (X0, X1)(C251, C252) is 5kHz on ES2/EX2
model, 10kHz on SS2/SX2 model and 50kHz on 32ES211T and SA2 model.
5.
The max frequency of the 2-phase 2-input counter (X2, X3)(C253, C254) is 5kHz on
ES2/EX2/SA2 model, 10 kHz on SS2/SX2 model and 50kHz on 32ES211T.
6.
2-phase 2-input counting supports double and 4 times frequency, which is selected in D1022
as the table in next page. Please refer to the below table for detailed counting wave form.
D1022
Counting mode
A
B
up co
unt
down
coun
t
A
B
up co
unt
down
coun
t
K2
(Double Frequency)
A
B
up
co
un
t
dow
n co
unt
A
B
up
co
un
t
dow
n co
unt
K4 or other value
(Quadruple frequency)
(Default)