3 . I n s t r u c t i o n S e t

3 - 1 6 3

API Mnemonic

Operands

Function

63

INCD

Incremental drum

sequencer

Controllers

ES2/EX2 SS2 SA2

SE

SX2

Bit Devices

Word devices

Program Steps

Type

OP

X Y

M S K H KnX KnY KnM KnS T C D E F

S

1

*

*

*

*

*

*

*

S

2

*

D

*

*

*

n

*

*

INCD: 9 steps

PULSE 16-bit 32-bit

ES2/EX2 SS2

SA2

SE

SX2 ES2/EX2 SS2

SA2

SE

SX2 ES2/EX2 SS2

SA2

SE

SX2

Operands:

S

1

: Start device of the data table S

2

: No. of counter D: Start device for indicating comparison

result n: Number of data to be compared (n: 1~64)

Explanations:

113. INCD instruction creates various output wave forms according to the current value of the

counter designated by S

2.

and S

2.

+1. Usually, the instruction is applied for relative cam control

114. The current value in S

2

is compared with the set points specified by S

1

(n consecutive devices)

When value in S

2

reaches the first set point, S

2.

+1 counts once for indicating the number of

present section, associated D turns ON, and S

2

is reset then counts up from 0 again. When the

drive contact of INCD instruction is OFF, the content in S

2.

and S

2.

+1 will be cleared.

115. When operand S

1

uses KnX, KnY, KnM, KnS patterns, Kn should be K4 for 16-bit instruction.

116. Operand S

2

should be C0~C198 and occupies 2 consecutive counters.

117. When the comparison of n data has been completed, the execution completed flag M1029 =

ON for one scan cycle.

Program Example:

118. Before the execution of INCD instruction, use MOV instruction to write all the set values into

D100 ~ D104 in advance. D100 = 15, D101 = 30, D102 = 10, D103 = 40, D104 = 25.

119. The current value of counter C10 is compared against the set-point value of D100~D104.

Once the current value is equal to the set-point value, C10 will be reset and count up from 0

again. Meanwhile C11 counts once for indicating the number of present section

120. When the content of C11 increase 1, M10~M14 will be ON sequentially. Please refer to the

following timing diagram.

121. When the comparison of 5 data has been completed, the execution completed flag M1029 =

ON for one scan cycle and C11 is reset for next comparison cycle.