3 . I n s t r u c t i o n S e t

3 - 3 8 9

API Mnemonic

Operands

Function

170

D GRY P

BIN

→ Gray Code

Controllers

ES2/EX2 SS2 SA2

SE

SX2

Bit Devices

Word devices

Program Steps

Type

OP

X Y

M S K H KnX KnY KnM KnS T C D E F

S

*

*

*

*

*

*

*

*

*

*

*

D

*

*

*

*

*

*

*

*

GRY, GRYP: 5 steps

DGRY, DGRYP: 9 steps

PULSE 16-bit 32-bit

ES2/EX2 SS2

SA2

SE

SX2 ES2/EX2 SS2

SA2

SE

SX2 ES2/EX2 SS2

SA2

SE

SX2

Operands:

S: Source device D: Operation result (Gray code)

Explanations:

1.

GRY instruction converts the BIN value in S to Gray Code and stores the converted result in

specified register D.

2.

Available range of S:

16-bit instruction: 0~32,767

32-bit instruction: 0~2,147,483,647

3. If

operand S exceeds the available range, operation error occurs and M1067 = ON, M1068 =

ON. D1067 stores the error code 0E1A (HEX)

4. If

operands

S and D use device F, only 16-bit instruction is applicable.

Program Example:

When X0 = ON, GRY instruction executes and converts K6513 to Gray Code. The operation result

is stored in K4Y20, i.e. Y20 ~ Y37.

X0

GRY

K6513

K4Y20

0 0 0 1 1

1

0 0

0 1 1 1

1

0 0 0

b15

b0

K6513=H1971

0 0 0

0

0

0 0

0 0 1

1

1

1

1

1

1

K4Y20

Y37

Y20

GRAY 6513