3-218

COM1

COM2

COM3

Function Description

- D1125 - Definition

of

ETX1

(RS)

- D1126 - Definition

of

ETX2

(RS)

D1249

D1129

D1252

Communication timeout setting (ms)

-

D1122

-

Residual number of words of transmitting data

-

D1256

~

D1295

-

Store the sent data of MODRW instruction.

-

D1089

~

D1099

-

Store the sent data of MODRD / MODWR / FWD

/ REV / STOP / RDST / RSTEF instruction

M1313 M1124 M1317

Data

receiving

ready

-

M1125

-

Communication ready status reset

- M1128 - Transmitting/Receiving status Indication

-

D1123

-

Residual number of words of the receiving data

-

D1070

~

D1085

-

Store the feedback data of Modbus

communication. RS instruction is not supported.

Data

receiving

D1167 D1168 D1169

Store the specific end word to be detected for

executing interrupts I140/I150/I160 (RS)

M1314 M1123 M1318

Data receiving completed

- M1127 -

COM2 (RS-485) data sending / receiving /

converting completed.

(RS instruction is not

supported)

- M1131 -

ON when MODRD/RDST/MODRW data is being

converted from ASCII to Hex

-

D1296

~

D1311

-

Store the converted HEX data of MODRW

instruction.

Receiving

completed

-

D1050

~

D1055

-

Store the converted HEX data of MODRD

instruction

M1315 - M1319

Data receiving error

D1250 - D1253

Communication

error

code

- M1129 - COM2 (RS-485) receiving time out

Errors

- M1140 -

COM2 (RS-485) MODRD/MODWR/MODRW

data receiving error

This manual is related to the following products: