beautypg.com

Delta DVP-ES2 User Manual

Page 58

background image

D V P - E S 2 / E X 2 / S S 2 / S A2 / S X 2 / S E O p e r a t i o n M a n u a l - P r o g r a m m i n g

2-26

Special

M

Function

ES2
EX2

SS2 SA2 SX2

OFF

Ø

ON

STOP

Ø

RUN

RUN

Ø

STOP

Attrib.

Latch

-ed

Default

M1346*

Output clear signals when ZRN is

completed

OFF

- -

R/W

NO

OFF

M1347

Auto-reset Y0 when high speed pulse

output is completed

OFF

- -

R/W

NO

OFF

M1348

Auto-reset Y1 when high speed pulse

output is completed

OFF

- -

R/W

NO

OFF

M1350* Enable PLC LINK

Off

- OFF

R/W

NO

OFF

M1351* Enable auto mode on PLC LINK

OFF

- -

R/W

NO

OFF

M1352* Enable manual mode on PLC LINK

OFF

- -

R/W

NO

OFF

M1353*

Enable access up to 50 words through

PLC LINK (If M1353 is ON,

D1480~D1511 are latched devices.)

OFF

- -

R/W

YES

OFF

M1354*

Enable simultaneous data read/write in a

polling of PLC LINK

OFF

- -

R/W

NO

OFF

M1355*

Select Slave linking mode in PLC LINK

(ON: manual; OFF: auto-detection)

- - -

R/W

YES

OFF

M1356*

Enable station number selection function.

When both M1353 and M1356 are ON,

the user can specify the station number

in D1900~D1931

- - -

R/W

YES

OFF

M1360* Slave ID#1 status on PLC LINK network

- - -

R/W

YES

OFF

M1361* Slave ID#2 status on PLC LINK network

- - -

R/W

YES

OFF

M1362* Slave ID#3 status on PLC LINK network

- - -

R/W

YES

OFF

M1363* Slave ID#4 status on PLC LINK network

- - -

R/W

YES

OFF

M1364* Slave ID#5 status on PLC LINK network

- - -

R/W

YES

OFF

M1365* Slave ID#6 status on PLC LINK network

- - -

R/W

YES

OFF

M1366* Slave ID#7 status on PLC LINK network

- - -

R/W

YES

OFF

M1367* Slave ID#8 status on PLC LINK network

- - -

R/W

YES

OFF

M1368* Slave ID#9 status on PLC LINK network

- - -

R/W

YES

OFF

M1369* Slave ID#10 status on PLC LINK network

- - -

R/W

YES

OFF

M1370* Slave ID#11 status on PLC LINK network

- - -

R/W

YES

OFF

M1371* Slave ID#12 status on PLC LINK network

- - -

R/W

YES

OFF

M1372* Slave ID#13 status on PLC LINK network

- - -

R/W

YES

OFF

M1373* Slave ID#14 status on PLC LINK network

- - -

R/W

YES

OFF

M1374* Slave ID#15 status on PLC LINK network

- - -

R/W

YES

OFF

M1375* Slave ID#16 status on PLC LINK network

- - -

R/W

YES

OFF

M1376*

Indicate Slave ID#1 data interchange

status on PLC LINK

OFF

- - R

NO

OFF

M1377*

Indicate Slave ID#2 data interchange

status on PLC LINK

OFF

- - R

NO

OFF

This manual is related to the following products: