beautypg.com

Delta DVP-ES2 User Manual

Page 581

background image

3 . I n s t r u c t i o n S e t

3 - 4 6 5

Points to note:

Relative flags and special D registers of COM2/COM3 :

COM2

COM3

Function Description

M1120 M1136

Retain communication setting

M1143

M1320

ASCII/RTU mode selection

D1120 D1109 Communication

protocol

Protocol

setting

D1121

D1255

PLC communication address

M1122 M1316

Sending

request

Sending

request

D1129

D1252

Communication timeout setting (ms)

Receiving

completed

M1127

M1318

Data receiving completed

-

M1319

Data receiving error

- D1253

Communication

error

code

M1129

-

Communication timeout setting (ms)

M1140 -

COM2 (RS-485) MODRD/MODWR/MODRW

data receiving error

M1141 -

MODRD/MODWR/MODRW parameter error

(Exception Code exists in received data)

Exception Code is stored in D1130

Errors

D1130 -

COM2 (RS-485) Error code (exception code)

returning from Modbus communication