D V P - E S 2 / E X 2 / S S 2 / S A2 / S X 2 O p e r a t i o n M a n u a l - P r o g r a m m i n g

3 - 4 0 4

2. Operand

D occupies 8 consecutive word registers. The function of each device is as below:

No.

Content

Range

Format

Note

D + 0~1 Zenith

0 ~ 90

Float

Horizontal=0

D + 2~3 Azimuth

0 ~ 360

Float

North point=0

D + 4~5 Incidence

0 ~ 90

Float

D + 6

Converted DA value of Zenith

0 ~ 2000

Word

1LSB = 0.045

degree

D + 7

Converted DA value of Azimuth

0 ~ 2000

Word

1LSB = 0.18

degree

3. The execution time of SPA instruction costs up to 50ms, therefore we suggest users to

execute this instruction with an interval not less than 1 sec, preventing the instruction from

taking too much PLC operation time.

4. Definition

of

Zenith:

0° and 45°.

0° 45°

5. Definition

of

Azimuth:

N

90°

180°

270°

N

90°

180°

270°

6.

The correct time of the local longitude: If we suppose that it is AM8:00:00 in Taipei, and the

longitude is 121.55 degrees east, then the correct time of the local longitude in Taipei should

be AM8:06:12. Please refer to API168 DTM instruction (parameter k11) for more explanation.