Delta DVP-ES2 User Manual
Page 72
D V P - E S 2 / E X 2 / S S 2 / S A2 / S X 2 / S E O p e r a t i o n M a n u a l - P r o g r a m m i n g
2-40
Special
D
Content
ES2
EX2
SS
2
SA
2
SX
2
OFF
Ø
ON
STOP
Ø
RUN
RUN
Ø
STOP
Attrib.
Latch
-ed
Default
D1023*
Register for Storing detected pulse width (unit:
0.1ms)
○
○
○
○
0 - -
R/W
NO 0
D1025* Code for communication request error
○
○
○
○
0 - - R
NO 0
D1026*
Pulse number for masking Y0 when M1156 = ON
(Low word)
○
○
○
○
0 0 -
R/W
NO 0
D1027*
Pulse number for masking Y0 when M1156 = ON
(High word)
○
○
○
○
0 0 -
R/W
NO 0
D1028 Index register E0
○
○
○
○
0 - -
R/W
NO 0
D1029 Index register F0
○
○
○
○
0 - -
R/W
NO 0
D1030 PV of Y0 pulse output (Low word)
○
○
○
○
- - -
R/W
YES
0
D1031 PV of Y0 pulse output (High word)
○
○
○
○
- - -
R/W
YES
0
D1032 PV of Y1 pulse output (Low word)
○
○
○
○
0 - -
R/W
NO 0
D1033 PV of Y1 pulse output (High word)
○
○
○
○
0 - -
R/W
NO 0
D1036* COM1 (RS-232) communication protocol
○
○
○
○
H’86
- -
R/W
NO
H’86
D1037*
Register for setting 8-sets SPD function (has to be
used with M1037)
○
○
○
○
0 - -
R/W
NO 0
D1038
1. Delay time setting for data response when PLC
is SLAVE in COM2 / COM3 RS-485
communication. Range: 0 ~ 10,000 (unit: 0.1ms).
2. By using PLC LINK in COM2 (RS-485), D1038
can be set to send next communication data with
delay. Range: 0 ~ 10,000 (Unit: one scan cycle)
○
○
○
○
- - -
R/W
NO 0
D1039* Fixed scan time (ms)
○
○
○
○
0 - -
R/W
NO 0
D1040 No. of the 1st step point which is ON.
○
○
○
○
0 - - R
NO 0
D1041 No. of the 2nd step point which is ON
○
○
○
○
0 - - R
NO 0
D1042 No. of the 3rd step point which is ON.
○
○
○
○
0 - - R
NO 0
D1043 No. of the 4th step point which is ON
○
○
○
○
0 - - R
NO 0
D1044 No. of the 5th step point which is ON.
○
○
○
○
0 - - R
NO 0
D1045 No. of the 6th step point which is ON
○
○
○
○
0 - - R
NO 0
D1046 No. of the 7th step point which is ON.
○
○
○
○
0 - - R
NO 0
D1047 No. of the 8th step point which is ON
○
○
○
○
0 - - R
NO 0
D1049 No. of alarm which is ON
○
○
○
○
0 - - R
NO 0
D1050
↓
D1055
Converted data for Modbus communication data
processing. PLC automatically converts the ASCII
data in D1070~D1085 into Hex data and stores
the 16-bit Hex data into D1050~D1055
○
○
○
○
0 - - R
NO 0
D1062*
Average number of times an analog signal is input
to the EX2/SX2 series PLC
The default value is K10 for EX2 version 2.6 and
version 2.8.
○
╳
╳
○
2 - -
R/W
YES
2
D1067* Error code for program execution error
○
○
○
○
0 0 - R
NO 0
D1068* Address of program execution error
○
○
○
○
0 - - R
NO 0