D V P - E S 2 / E X 2 / S S 2 / S A2 / S X 2 / S E O p e r a t i o n M a n u a l - P r o g r a m m i n g

2-40

Special

D

Content

ES2
EX2

SS

2

SA

2

SX

2

OFF

Ø

ON

STOP

Ø

RUN

RUN

Ø

STOP

Attrib.

Latch

-ed

Default

D1023*

Register for Storing detected pulse width (unit:
0.1ms)

0 - -

R/W

NO 0

D1025* Code for communication request error

0 - - R

NO 0

D1026*

Pulse number for masking Y0 when M1156 = ON
(Low word)

0 0 -

R/W

NO 0

D1027*

Pulse number for masking Y0 when M1156 = ON
(High word)

0 0 -

R/W

NO 0

D1028 Index register E0

0 - -

R/W

NO 0

D1029 Index register F0

0 - -

R/W

NO 0

D1030 PV of Y0 pulse output (Low word)

- - -

R/W

YES

0

D1031 PV of Y0 pulse output (High word)

- - -

R/W

YES

0

D1032 PV of Y1 pulse output (Low word)

0 - -

R/W

NO 0

D1033 PV of Y1 pulse output (High word)

0 - -

R/W

NO 0

D1036* COM1 (RS-232) communication protocol

H’86

- -

R/W

NO

H’86

D1037*

Register for setting 8-sets SPD function (has to be
used with M1037)

0 - -

R/W

NO 0

D1038

1. Delay time setting for data response when PLC
is SLAVE in COM2 / COM3 RS-485
communication. Range: 0 ~ 10,000 (unit: 0.1ms).

2. By using PLC LINK in COM2 (RS-485), D1038
can be set to send next communication data with
delay. Range: 0 ~ 10,000 (Unit: one scan cycle)

- - -

R/W

NO 0

D1039* Fixed scan time (ms)

0 - -

R/W

NO 0

D1040 No. of the 1st step point which is ON.

0 - - R

NO 0

D1041 No. of the 2nd step point which is ON

0 - - R

NO 0

D1042 No. of the 3rd step point which is ON.

0 - - R

NO 0

D1043 No. of the 4th step point which is ON

0 - - R

NO 0

D1044 No. of the 5th step point which is ON.

0 - - R

NO 0

D1045 No. of the 6th step point which is ON

0 - - R

NO 0

D1046 No. of the 7th step point which is ON.

0 - - R

NO 0

D1047 No. of the 8th step point which is ON

0 - - R

NO 0

D1049 No. of alarm which is ON

0 - - R

NO 0

D1050

D1055

Converted data for Modbus communication data
processing. PLC automatically converts the ASCII
data in D1070~D1085 into Hex data and stores
the 16-bit Hex data into D1050~D1055

0 - - R

NO 0

D1062*

Average number of times an analog signal is input
to the EX2/SX2 series PLC

The default value is K10 for EX2 version 2.6 and
version 2.8.

2 - -

R/W

YES

2

D1067* Error code for program execution error

0 0 - R

NO 0

D1068* Address of program execution error

0 - - R

NO 0