beautypg.com

Delta DVP-ES2 User Manual

Page 253

background image

3 . I n s t r u c t i o n S e t

3 - 1 3 7

API Mnemonic

Operands

Function

57

D PLSY

Pulse Output

Controllers

ES2/EX2 SS2 SA2

SE

SX2

Bit Devices

Word devices

Program Steps

Type

OP

X Y

M S K H KnX KnY KnM KnS T C D E F

S

1

* *

*

*

*

*

*

*

*

*

*

S

2

* *

*

*

*

*

*

*

*

*

*

D

*

PLSY: 7 steps

DPLSY: 13 steps

PULSE 16-bit 32-bit

ES2/EX2 SS2

SA2

SE

SX2 ES2/EX2 SS2

SA2

SE

SX2 ES2/EX2 SS2

SA2

SE

SX2

Operands:

S

1

: Pulse output frequency S

2

: Number of output pulses D: Pulse output device (Y0 ~ Y3

available)

Explanations:

21. When PLSY instruction has been executed, the specified quantity of pulses S

2

will be output

through the pulse output device D at the specified pulse output frequency S

1

22. S

1

specifies the pulse output frequency

Output frequency range of MPU

Output

Y0, Y2

Y1, Y3

16-bit instruction

SS2: 0~10,000Hz

ES2/EX2/SA2/SX2/SE: 0~32,767 Hz

0~10,000Hz

range

32-bit instruction

SS2: 0~10,000Hz

ES2/EX2/SA2/SX2/SE: 0~100,000 Hz

0~10,000Hz

If frequency equals or smaller than 0Hz is specified, pulse output will be disabled.

If frequency bigger than max frequency is specified, PLC will output with max frequency.

23. S

2

specifies the number of output pulses.

16-bit instruction: -32,768~32,767. 32-bit instruction: -2,147,483,648~2,147,483,647.

When S

2

is specified as K0, the pulse will be output continuously regardless of the limit of

pulse number.

24. When D1220/D1221 = K1 or K2, the positive/negative sign of S

2

denotes pulse output direction

(Positive/negative).

This manual is related to the following products: