Delta DVP-ES2 User Manual
Page 396
D V P - E S 2 / E X 2 / S S 2 / S A2 / S X 2 / S E O p e r a t i o n M a n u a l - P r o g r a m m i n g
3-280
Registers for data to be sent (sending messages)
Register
Data
Descriptions
D1089 low
‘C’
43 H
Header of control string
D1090 low
‘
♥’ 03
H
Checksum
D1091 low
‘
☺’ 01
H
Command acknowledgement
(communication mode)
D1092 low
‘0’
30 H
D1093 low
‘0’
30 H
D1094 low
‘0’
30 H
D1095 low
‘1’
31 H
Communication address
D1096 low
‘0’
30 H
D1097 low
‘5’
35 H
D1098 low
‘0’
30 H
D1099 low
‘0’
30 H
Operation command
Registers for received data (responding messages)
Register
DATA
Explanation
D1070 low
‘C’
43 H
Header of control string
D1071 low
‘
♥’ 03
H
Checksum
D1072 low
‘
♠’ 06
H
Acknowledge back. (Check feedback data)
(correct: 06H, Error: 07 H)
D1073 low
‘0’
30 H
D1074 low
‘0’
30 H
D1075 low
‘0’
30 H
D1076 low
‘1’
31 H
Communication address
D1077 low
‘0’
30 H
D1078 low
‘5’
35 H
D1079 low
‘0’
30 H
D1080 low
‘0’
30 H
Operation command
2.
M1177 = ON, other Delta VFDs are supoported
a)
S
1
= Address of VFD-A. Range of S
1
: K0 ~ K255, when S
1
is specified as K0, PLC will
broadcast to all connected VFDs.
b)
S
2
= Running frequency of VFD. Please refer to manuals of specific VFD. In STOP
instruction, operand S
2
is reserved.
c)
n = Operation mode.
In FWD instruction: n = 0
Forward mode; n = 1
Forward JOG. Other values
will be regarded as normal forward mode.
In REV instruction: n = 0
Reverse mode; n = 1
Reverse JOG. Other values
will be regarded as normal reverse mode