D V P - E S 2 / E X 2 / S S 2 / S A2 / S X 2 / S E O p e r a t i o n M a n u a l - P r o g r a m m i n g

3 - 1 5 0

output will stop after 1,000,000 pulses are completed.

„

When pulse output ramps down and stops after Mark is detected, M1538 will be ON to

indicate the pause status. If users need to complete the remaining pulses, set OFF the

flag M1108 and pulse output will resume.

74. Operation of Mask function on Y0:

Frequency

Start/end
frequency

Target
speed

Y0 is masked from
interrupts on X4

Y0 is ready for
interrupts from X4

Pulse number if no
external interrupt on X 4

Time

D1340

Pulses to be m asked,

Ramp down time
(D1348)

Specified by DD1026

Ramp-down stop pulse
number when M ark
is detected (D

)

D1232

Pulse
number

„

Mask function on Y0 will be enabled when D1026 and D1027 are specified with values other

than 0. Mask function is disabled when D1026 and D1027 are specified with 0. If pulse output

process can not reach the target speed, PLC will clear DD1026 to disable the Mask function. If

the Mask range is set to be within the ramp-up section, PLC will automatically modify DD1026

to be longer than the ramp-up section. On the other hand, if DD1026 is set between ramp-

down section, PLC will modify DD1026 to be the range before the beginning of ramp-down

process. Mask function setting method on Y2 is the same as Y0.

Program example 2:

M0

Y0

M0

M1000

I401

SET

M1156

DMOV

DPLSR K100000 K1000000

K20

FEND

INCP

D0

IRET

END

DMOV

K10000

D1232

K50000

D1026