D V P - E S 2 / E X 2 / S S 2 / S A2 / S X 2 / S E O p e r a t i o n M a n u a l - P r o g r a m m i n g

3 - 3 3 8

3.

Take the connection between PLC (PLC COM2) and VFD-B for example, the tables below

explains the status when PLC reads status of VFD-B. (M1143 = OFF, ASCII Mode) (M1143 =

ON, RTU Mode)

H87

MOV

M1002

D1120

SET

M1120

K100

MOV

D1129

RST

M1127

Set communication protocol as 9600, 8, E, 1

Retain communication protocol

Set communication timeout as 100ms

MODRW

K3

K1

X0

H2100

D0

K6

Connection device
address: K1

Function code: K3
read multiple words

Data address: H2100

Data storing register

Data length(word)

Processing received data

ASCII mode : The received ASCII data is stored in registers starting from D0
and PLC converts the ASCII data to Hex value and stores them in
D1296~D1301 automatically.

RTU mode : The received data is stored in registers starting from D0 in Hex value.

Reset M1127

M1127

SET

X0

M1122

Sending request

M1143 = OFF
ASCII mode

RST

M1143

M1143 = ON
RTU mode

SET

M1143

Receiving completed

ASCII mode (M1143 = OFF):

When X0 = ON, MODRW instruction executes the function specified by Function Code 03

PLC

Ö VFD-B, PLC sends: “01 03 2100 0006 D5”

VFD-B

Ö PLC, PLC receives: “01 03 0C 0100 1766 0000 0000 0136 0000 3B”

Registers for data to be sent (sending messages)

Register

Data

Descriptions

D1256 Low byte

‘0’

30 H

ADR 1

D1256 High byte

‘1’

31 H

ADR 0

Address of VFD-B: ADR (1,0)

D1257 Low byte

‘0’

30 H

CMD 1

D1257 High byte

‘3’

33 H

CMD 0

Control parameter: CMD (1,0)

D1258 Low byte

‘2’

32 H

D1258 High byte

‘1’

31 H

D1259 Low byte

‘0’

30 H

D1259 High byte

‘0’

30 H

Data Address