Delta DVP-ES2 User Manual
Page 519
3 . I n s t r u c t i o n S e t
3 - 4 0 3
API Mnemonic
Operands
Function
178
D SPA
Solar Panel
Positioning
Controllers
ES2/
EX2
SS2
SA2 SX2
SE
Bit Devices
Word devices
Program Steps
Type
OP
X Y
M S K H KnX KnY KnM KnS T C D E F
S
*
*
*
D
*
DSPA: 9 steps
PULSE 16-bit 32-bit
ES2/
EX2
SS2 SA2 SX2 SE
ES2/
EX2
SS2 SA2 SX2 SE
ES2/
EX2
SS2 SA2 SX2 SE
Operands:
S: Start device for input parameters D: Start device for output parameters
Explanations:
1. Operand S occupies 208 consecutive word registers. The function of each device is as below:
No.
Content
Range
Format
Note
S + 0
Year 2000
~
Word
S + 1
Month
1 ~ 12
Word
S + 2
Day
1 ~ 31
Word
S + 3
Hour
0 ~ 23
Word
S + 4
Minute
0 ~ 59
Word
S + 5
Second
0 ~ 59
Word
Please enter the
correct time of the local
longitude. Please refer
to DTM (parameter 11)
for the conversion
formula. A simple
illustration is as in point
6.
S + 6~7
Time difference (
Δt) (sec)
± 8000
Float
S + 8~9
Local time zone
± 12
Float
West: negative
S + 10~11 Longitude
± 180
Float
West: negative
Unit: degree
S + 12~13 Latitude
± 90
Float
South: negative Unit:
degree
S + 14~15 Elevation 0~
6500000
Float Unit:
meter
S + 16~17 Pressure
0 ~ 5000
Float
Unit: millibar
S + 18~19 Mean annual temperature (MAT)
-273~6000
Float
Unit: °C
S + 20~21 Slope ±
360
Float
S + 22~23 Azimuth ±
360
Float
S + 24~25 Atmospheric refraction between
sunrise and sunset
± 5
Float
S +26~207 Reserved for system operation