Delta DVP-ES2 User Manual
Page 552
D V P - E S 2 / E X 2 / S S 2 / S A2 / S X 2 O p e r a t i o n M a n u a l - P r o g r a m m i n g
3 - 4 3 6
2. Steps:
a) Find the max. and min. coordinates on X and Y axes (0,0), (26000,26000), (34000,18000),
(8000,-8000) (as the figure above). Place them respectively in the 32-bit registers
(D200,D202), (D204,D206), (D208,D210) and (D212,D214).
b) Select “draw clockwise arc” and default “motion time” (S = D100 = K0).
c) RUN the PLC. Set ON M0 to start the drawing of a tilted ellipse.
D214
M1029
DCIMA
Y0
END
D210
DCIMA
Y0
D206
DCIMA
Y0
D202
DCIMA
Y0
= D0 K1
= D0 K2
= D0 K4
M0
K1
D0
D0
M0
M1029
K0
D1030
D100
D100
D100
D100
K0
D100
K0
D1336
D212
D208
D204
D200
= D0 K3
RST
DMOV
DMOV
MOV
MOV
INCP
3. Operation:
When PLC runs and M0 = ON, PLC will start the drawing of the first segment of the arc. D0 will
plus 1 whenever a segment of arc is completed and the second segment of the arc will start to
execute automatically. The operation pattern repeats until the fourth segment of arc is
completed.