Delta DVP-ES2 User Manual
Page 52
D V P - E S 2 / E X 2 / S S 2 / S A2 / S X 2 / S E O p e r a t i o n M a n u a l - P r o g r a m m i n g
2-20
Special
M
Function
ES2
EX2
SS2 SA2 SX2
OFF
Ø
ON
STOP
Ø
RUN
RUN
Ø
STOP
Attrib.
Latch
-ed
Default
M1086
Enabling password function for DVP-
PCC01
○
○
○
○
OFF
- -
R/W
NO
OFF
M1088
Matrix comparison.
Comparing between equivalent values
(M1088 = ON) or different values (M1088
= OFF).
○
○
○
○
OFF
OFF
- R/W
NO OFF
M1089
Indicating the end of matrix comparison.
When the comparison reaches the last bit,
M1089 = ON.
○
○
○
○
OFF
OFF
- R
NO
OFF
M1090
Indicating start of matrix comparison.
When the comparison starts from the first
bit, M1090 = ON.
○
○
○
○
OFF
OFF
- R
NO
OFF
M1091
Indicating matrix searching results. When
the comparison has matched results,
comparison will stop immediately and
M1091 = ON.
○
○
○
○
OFF
OFF
- R
NO
OFF
M1092
Indicating pointer error. When the pointer
Pr exceeds the comparison range, M1092
= ON
○
○
○
○
OFF
OFF
- R
NO
OFF
M1093
Matrix pointer increasing flag. Adding 1 to
the current value of the Pr.
○
○
○
○
OFF
OFF
- R/W
NO OFF
M1094
Matrix pointer clear flag. Clear the current
value of the Pr to 0
○
○
○
○
OFF
OFF
- R/W
NO OFF
M1095
Carry flag for matrix rotation / shift /
output.
○
○
○
○
OFF
OFF
- R
NO
OFF
M1096 Borrow flag for matrix rotation/shift/input
○
○
○
○
OFF
OFF
- R/W
NO OFF
M1097
Direction flag for matrix
rotation/displacement
○
○
○
○
OFF
OFF
- R/W
NO OFF
M1098
Counting the number of bits which are “1”
or “0”
○
○
○
○
OFF
OFF
- R/W
NO OFF
M1099 ON when the bits counting result is “0”
○
○
○
○
OFF
OFF
- R/W
NO OFF
M1102*
Y2/CH1 (Y2, Y3) pulse output execution
completed
○
○
○
○
OFF
- -
R/W
NO
OFF
M1103* Y3 pulse output completed
○
○
○
○
OFF
- -
R/W
NO
OFF
M1104
Y2/CH1 (Y2, Y3) pulse output pause
(immediate)
○
○
○
○
OFF
OFF
- R/W
NO OFF
M1105 Y3 pulse output pause (immediate)
○
○
○
○
OFF
OFF
- R/W
NO OFF
M1106
Zero point selection. M1106=ON, change
the zero point to the right of DOG switch
for zero return on CH0.
○
○
○
○
OFF
OFF
- R/W
NO OFF
M1107
Zero point selection. M1107=ON, change
the zero point to the right of DOG switch
for zero return on CH1.
○
○
○
○
OFF
OFF
- R/W
NO OFF
M1108
Y0/CH0 (Y0, Y1) pulse output pause
(ramp down)
○
○
○
○
OFF
OFF
- R/W
NO OFF