Displaying MPLS BFD information

25

Displaying MPLS BFD global configuration information

You can use the show mpls bfd command to display the global configuration information for a
device, as shown in the following.

Syntax: show mpls bfd

TABLE 133

Display of BFD MPLS detail command

This field...

Displays...

MPLS BFD admin

The global configuration state of MPLS BFD on the device: can be either
Enabled or Disabled

Minimum TX interval

Desired Min Tx Interval - the minimum interval, in microseconds, the local
system will use when transmitting BFD Control packets. The value zero is
reserved.

Minimum RX interval

Required Min Rx Interval - the mimi num interval, in microseconds, between
received BFD Control packets that this system is capable of supporting. If this
value is zero, the transmitting system does not want the remote system to
send any periodic BFD Control packets.

Detection time multiplier

The number of times in a single sequence this device waits to receive a BFD
message from the peer before determining that the connection to that peer is
not operational.

Brocade# show mpls bfd

MPLS BFD admin = Enabled

Minimum TX interval = 1000 msec

Minimum RX interval = 1000 msec

Detection time multiplier = 3