ERP over ESI VLAN (Brocade NetIron CES and Brocade NetIron CER)

15

The interconnection nodes play a vital role in traffic forwarding and should be aware of ERP
instances associated with each other within the node. In

Figure 146

, the DUT17 interconnection

node needs to be aware of Ring 1 being a sub-ring of the Ring 2 ERP instance. This association is
important as it is required to perform a FDB flush in Ring-2 on receiving R-APS (SF) messages from
Ring-1 .

Interconnection Rings with same VLANs

The PBB case such as in

Figure 147

, where one B-VLAN span across multiple rings, the ring

mapping will still be maintained as it helps push the events from sub-rings to major ring.

The PB case will be also handled similarly.

FIGURE 147

ERP configuration with same VLAN

Sample configurations

PB ring node

FIGURE 148

PB ring node sample configuration

PE-2 Configuration with S-VLAN 200:

!

esi svlan encapsulation svlan

vlan 200

tagged ethe 1/1 ethe 1/2

!

erp 200

left-interface esi svlan vlan 200 ethe 1/1

right-interface esi svlan vlan 200 ethe 1/2

rpl-owner

sub-ring

rpl esi svlan vlan 200 ethe 1/2