beautypg.com

Displaying bfd for bgp4, Displaying bfd information – Brocade Multi-Service IronWare Switching Configuration Guide (Supporting R05.6.00) User Manual

Page 958

background image

928

Multi-Service IronWare Switching Configuration Guide

53-1003036-02

Configuring BFD for the specified protocol

25

Displaying BFD for BGP4

You can display BFD for BGP4 information for the device you are logged in to and for BFD
configured neighbors as described in the following sections.

Displaying BFD information

The following example illustrates the output from the show bfd command:

Brocade# show bfd

BFD State: ENABLED Version: 1 Use PBIF Assist: Y

Current Registered Protocols: bgp/1 ospf6/0 ospf/0 bgp/0

All Sessions: Current: 0 Maximum Allowed: 100 Maximum Exceeded Count: 0

LP Sessions: Maximum Allowed on LP: 20 Maximum Exceeded Count for LPs: 0

LP Tx/Rx Sessions LP Tx/Rx Sessions LP Tx/Rx Sessions LP Tx/Rx Sessions

1 0/0 2 0/0 3 0/0 4 0/0

5 0/0 6 0/0 7 0/0 8 0/0

9 0/0 10 0/0 11 0/0 12 0/0

13 0/0 14 0/0 15 0/0 16 0/0

BFD Enabled ports count: 0

Syntax: show bfd

This display shows the following information.

TABLE 127

Display of BFD information

This field...

Displays...

BFD State

Specifies if BFD is Enabled or Disabled on the device.

Version

Specifies the version of the BFD protocol operating on the device.

Using PBIF Assist

Specifies the status of the PCI Bus Interface (PBIF) Assist.

Current Registered Protocols

Specifies which protocols are registered to use BFD on the device.
Possible values are mpls/0, ospf/0, ospf6/0, or isis/0 or bgp/0

All Sessions

Current:

The number of BFD sessions currently operating on the device.

Maximum Allowed

The maximum number of BFD sessions that are allowed on the device.
The maximum number of sessions supported on a device is 250 for
Ni-XMR and Ni-MLX and 40 for Ni-CES.

Maximum Exceeded Count

The number of times the request to set up a BFD session was declined
because it would have exceeded the maximum number of BFD sessions
allowed on the device.

LP Sessions:

Maximum Allowed on LP

The maximum number of BFD sessions allowed on an interface module.
The maximum number of sessions supported is 40 for Ni-XMR and
Ni-MLX, and 20 for Ni-CES

Maximum Exceeded Count for LPs The number of times the request to set up a BFD session was declined

because it would have exceeded the maximum number of BFD sessions
allowed on an interface module.

LP

The number of the interface modules for which the Current Session
Count is displayed.