Displaying bfd for bgp4, Displaying bfd information – Brocade Multi-Service IronWare Switching Configuration Guide (Supporting R05.6.00) User Manual
Page 958
928
Multi-Service IronWare Switching Configuration Guide
53-1003036-02
Configuring BFD for the specified protocol
25
Displaying BFD for BGP4
You can display BFD for BGP4 information for the device you are logged in to and for BFD
configured neighbors as described in the following sections.
Displaying BFD information
The following example illustrates the output from the show bfd command:
Brocade# show bfd
BFD State: ENABLED Version: 1 Use PBIF Assist: Y
Current Registered Protocols: bgp/1 ospf6/0 ospf/0 bgp/0
All Sessions: Current: 0 Maximum Allowed: 100 Maximum Exceeded Count: 0
LP Sessions: Maximum Allowed on LP: 20 Maximum Exceeded Count for LPs: 0
LP Tx/Rx Sessions LP Tx/Rx Sessions LP Tx/Rx Sessions LP Tx/Rx Sessions
1 0/0 2 0/0 3 0/0 4 0/0
5 0/0 6 0/0 7 0/0 8 0/0
9 0/0 10 0/0 11 0/0 12 0/0
13 0/0 14 0/0 15 0/0 16 0/0
BFD Enabled ports count: 0
Syntax: show bfd
This display shows the following information.
TABLE 127
Display of BFD information
This field...
Displays...
BFD State
Specifies if BFD is Enabled or Disabled on the device.
Version
Specifies the version of the BFD protocol operating on the device.
Using PBIF Assist
Specifies the status of the PCI Bus Interface (PBIF) Assist.
Current Registered Protocols
Specifies which protocols are registered to use BFD on the device.
Possible values are mpls/0, ospf/0, ospf6/0, or isis/0 or bgp/0
All Sessions
Current:
The number of BFD sessions currently operating on the device.
Maximum Allowed
The maximum number of BFD sessions that are allowed on the device.
The maximum number of sessions supported on a device is 250 for
Ni-XMR and Ni-MLX and 40 for Ni-CES.
Maximum Exceeded Count
The number of times the request to set up a BFD session was declined
because it would have exceeded the maximum number of BFD sessions
allowed on the device.
LP Sessions:
Maximum Allowed on LP
The maximum number of BFD sessions allowed on an interface module.
The maximum number of sessions supported is 40 for Ni-XMR and
Ni-MLX, and 20 for Ni-CES
Maximum Exceeded Count for LPs The number of times the request to set up a BFD session was declined
because it would have exceeded the maximum number of BFD sessions
allowed on an interface module.
LP
The number of the interface modules for which the Current Session
Count is displayed.