Displaying bfd information – Brocade Multi-Service IronWare Switching Configuration Guide (Supporting R05.6.00) User Manual
Page 946
916
Multi-Service IronWare Switching Configuration Guide
53-1003036-02
Displaying BFD information
25
Displaying BFD information
You can display BFD information for the device you are logged-in to and for BFD-configured
neighbors as described in the following sections.
Displaying BFD information
The following example illustrates the output from the show bfd command:
Brocade# show bfd
BFD State: ENABLED Version: 1 Use PBIF Assist: Y
Current Registered Protocols: ospf/0 ospf6/0
All Sessions: Current: 4 Maximum Allowed: 100 Maximum Exceeded Count: 0
LP Sessions: Maximum Allowed on LP: 40 Maximum Exceeded Count for LPs: 0
LP Tx/Rx Sessions LP Tx/Rx Sessions LP Tx/Rx Sessions LP Tx/Rx Sessions
1 4/4 2 2/2 3 0/0 4 0/0
5 0/0 6 0/0 7 0/0 8 0/0
9 0/0 10 0/0 11 0/0 12 0/0
13 0/0 14 0/0 15 0/0 16 0/0
BFD Enabled ports count: 2
Port MinTx MinRx Mult Sessions
eth 2/1 100 100 3 2
eth 3/1 100 100 3 2
Syntax: show bfd
This display shows the following information.
TABLE 124
Display of BFD information
This field...
Displays...
BFD State
Specifies if BFD is Enabled or Disabled on the device.
Version
Specifies the version of the BFD protocol operating on the device.
Use PBIF Assist
Specifies the status of PCI Bus Interface (PBIF) Assist.
Current Registered Protocols
Specifies which protocols are registered to use BFD on the device.
Possible values are mpls/0, ospf/0, ospf6/0, or isis_task/0
All Sessions
Current:
The number of BFD sessions currently operating on the device.
Maximum Allowed
The maximum number of BFD sessions that are allowed on the device.
The maximum number of sessions supported on a device is 250 for
Ni-XMR and Ni-MLX and 40 for Ni-CES.
Maximum Exceeded Count
The number of times the request to set up a BFD session was declined
because it would have resulted in exceeding the maximum number of
BFD sessions allowed on the device.
LP Sessions:
Maximum Allowed on LP
The maximum number of BFD sessions that are allowed on an interface
module. The maximum number of sessions supported on an interface
module is 40 for Ni-XMR and Ni-MLX and 20 for Ni-CES
Maximum Exceeded Count for LPs The number of times the request to set up a BFD session was declined
because it would have resulted in exceeding the maximum number of
BFD sessions allowed on an interface module.