802.1ag over PBB OAM

11

Faults can be detected using Continuity Check messages at any of the four MA categories. Once a
fault is detected, Link Trace can be used to narrow down the location of the fault. Depending on the
location of the fault, a different MA category may need to be used to further isolate the location of
the fault.

802.1ag for Link MA

A new MA type is supported for Link MA.

Brocade(config- dot1ag -DONAME) #ma-name MANAME link-MA priority 4

Brocade(config- dot1ag -DONAME-MANAME) # mep 2 down port eth 1/1

Syntax: ma-name MANAME {vlan-id vlan-id | vpls-id vpls-id | [vll [vll-name]|[vll-id]|vll-local

[vll-name] | link-MA } priority priority

Only the down MEP configuration is allowed for a link-MA.

Syntax: mep mep-id [ up | down ] [ vlan vlan-id port port-id | port port-id ]

Error messages

If an up MEP command is issued the following error message is displayed.

Brocade(config- dot1ag -DONAME-MANAME) # mep 2 up port eth 1/1

Error : UP MEP cannot be configured on LINK-MA

MEP configuration for link MA is rejected if more than one port is entered in the configuration.

Brocade(config- dot1ag -DONAME-MANAME) # mep 2 down port eth 1/1 to 1/3

Error : MEP cannot be configured on multiple ports for Link MA

MIP operation is not allowed for link MA. An error is displayed if the MIP-POLICY command is
issued.

Brocade(config- dot1ag -DONAME-MANAME)#mip-policy explicit

Error: MIP cannot be configured on LINK-MA

Link MA capabilities and limitations

MIP functionality is not supported for link-MA.

Link trace functionality is not supported for link-MA.

Loopback and delay measurement functionality is supported on link-MA.

802.1ag sub-second-timer functionality is supported for link-MA.

802.1ag functionality is supported during hitless upgrade and switchover.

802.1ag functionality is supported for LAG.

When MEP is configured on a VPLS instance with sub-second CCM timer, the MIP flooding
should be turned off. When there is no MEP and it is a sub-second-timer, then dot1ag flooding
should be turned on.

Brocade#show cfm

Domain: D10

Index: 3

Level: 7

Maintenance association: MA

Ma Index: 1

CCM interval: 10000 ms

LINK MA ID: 0