Multi-Service IronWare Switching Configuration Guide

535

53-1003036-02

ERP commands

15

Configuration example

NOTE

The VLAN CPU protection needs to be enabled on the VLANs.

Device 1 Configuration steps

CFM configuration:

Brocade#configure terminal

Brocade(config)#cfm-enable

Brocade(config-cfm)#domain-name erp id 1 level 1

Brocade(config-cfm-md-erp)#ma-name ma-erp link-ma priority 7

Brocade(config-cfm-md-erp-ma-ma-erp)#individual-link-monitoring

Brocade(config-cfm-md-erp-ma-ma-erp)#mep 101 down port eth 1/1

Brocade(config-cfm-md-erp-ma-ma-erp)#mep 102 down port eth 1/2

VLAN Configuration:

Brocade(config)#vlan 100

Brocade(config-vlan-100)#tag eth 1/1 eth 1/2

Brocade(config-vlan-100)#vlan-cpu-protection

ERP Configuration:

Brocade(config)#erp 1

Brocade(config-erp-1)#left-interface vlan 100 eth 1/1

Brocade(config-erp-1)#right-interface vlan 100 eth 1/2

Brocade(config-erp-1)#rpl-owner

Brocade(config-erp-1)#rpl vlan 100 eth 1/2

Brocade(config-erp-1)#flooding-enable

Brocade(config-erp-1)#fdb-flush-optimization

Brocade(config-erp-1)#dot1ag-compliance domain-name erp ma-name ma-erp

Brocade(config-erp-1)#enable