beautypg.com

Brocade Multi-Service IronWare Switching Configuration Guide (Supporting R05.6.00) User Manual

Page 556

background image

526

Multi-Service IronWare Switching Configuration Guide

53-1003036-02

Forced switch

15

Next, the operator enters the no command to clear the forced switch. For this example, the
operator initiated the forced switch from ERN 4 and must clear it from ERN 4.

Figure 142

shows the

forced switch recovery process in sequential order.

FIGURE 142

FS clear process

RPL owner (ERN1)

Non-RPL node (ERN 2)

Non-RPL node (ERN 3)

Non-RPL node (ERN 4)

From the FS state, ERN 4:
1

Starts the guard timer

2

Stops transmitting
R-APS(FS

3

Transmits R-APS(NR)

4

Keeps blocking the
port

5

Enters Pending state

From FS state, ERN 1:
1

Forwards R-APS

2

Starts the guard timer

3

Starts the WTB timer

4

Enters Pending state

From FS state, ERN 2:
1

Forwards R-APS

2

Starts the guard timer

3

Enters the Pending
state

From FS state, ERN 3:
1

Forwards R-APS

2

Starts the guard timer

3

Enters the Pending
state

After the WTB timer expires,
from the Pending state ERN
1:
5. Blocks the RPL port
6. Transmits R-APS(NR,RB)
7. Unblocks the non-RPL port
8. Flushes the FDB
9. Enters the Idle state

From the Pending state,
ERN 2:
4. Flushes the FDB
5. Forwards R-APS(NR,RB)
6. Enters the Idle state

From the Pending state,
ERN 3:
4. Stops transmitting
R-APS
5. Unblocks ports
6. Flushes the FDB
7. Forwards R-APS(NR,RB)
Enters the idle state

From the Pending state,
ERN 4:
6. Stops transmitting
R-APS
7. Unblocks ports
8. Flushes the FDB
9. Forwards R-APS(NR,RB)
10. Enters the Idle state

From the idle state, ERN 1:
10. Receives its own
R-APS(NR,RB)
11. Stops transmitting R-APS
12. Remains in the Idle state