beautypg.com

Port loop detection, Loop detection for specific vlan on a port, Loop detection shutdown-disable – Brocade Multi-Service IronWare Switching Configuration Guide (Supporting R05.6.00) User Manual

Page 655: Loop-detection shutdown-sending-port

background image

Multi-Service IronWare Switching Configuration Guide

625

53-1003036-02

About Multi-Chassis Trunk (MCT)

18

Port loop detection

Port loop detection is used to detect L2 loops in MCT ( due to misconfiguration). When using MCT, it
requires the ICL ports to be strictly tagged. The port loop detection feature supports strictly tagged
ports.

Loop detection for specific VLAN on a port

Strict mode loop detection can be configured on a specific VLAN for a given port. To configure loop
detection on VLAN 10 for interface 1/1, enter a command such as the following.

Brocade(config-if-e1000-1/1)#loop-detection vlan 10

Syntax: [no] loop-detection [vlan ]

Where vlan-id enablesLoose Mode configuration for a VLAN group.

A port can be tagged or untagged member of this VLAN.

Multiple VLANs can have loop detection configured for a given port. Loop detection BPDUs will be
sent out of each configured VLAN on that port.

Loop detection shutdown-disable

Use the loop-detection shutdown-disable command to disable the port shutdown feature in case of
loop detection. This feature will ensure that the ICL stays up when a loop detection PDU is received
on the ICL. This command will be applied to both strict mode or loose mode loop detection. To
configure loop-detection shutdown-disable to shutdown port 1/1 used for the ICL link, enter a
command such as the following.

Brocade(config-if-e1000-1/1)#loop-detection shutdown-disable

Syntax: loop-detection shutdown-disable

Loop-detection shutdown-sending-port

By default, the receive-port is shutdown by loop detection. The loop-detection
shutdown-sending-port command will shutdown the port that sent the loop detection PDUs instead
of shutting down the receiving port. This will ensure that the ICL stays up when a loop detection
PDU is received on the ICL.

This feature is only applicable to strict mode loop detection.

Brocade(config-if-e1000-1/1)#loop-detection shutdown-sending-port

SuperSpan

03-80-c2-xx-xx-00

Flood to the VLAN

Same as non-MCT switch

VSRP Control

03-04-80-00-01-00

Flood to the VLAN

Same as non-MCT switch

VSRP Source

03-04-80-00-01-01

Flood to the VLAN

Same as non-MCT switch

Loop detection MAC

Base MAC address |

0x03000000

Flood to the VLAN

Same as non-MCT switch

TABLE 81

L2 protocol forwarding action –MCT switch and non - MCT switch

Protocol

Destination MAC

Non- MCT switch
forwarding action

MCT switch forwarding action