Brocade Multi-Service IronWare Switching Configuration Guide (Supporting R05.6.00) User Manual
Page 338
![background image](/manuals/361635/338/background.png)
308
Multi-Service IronWare Switching Configuration Guide
53-1003036-02
802.1ag over PBB OAM
11
2. Create a maintenance domain with a specified name CUST_1 and level 7.
Brocade(config-cfm)#domain-name CUST_1 level 7
3. Create a maintenance association within a specified domain of vlan-id 10 with a priority 3.
Brocade(config-cfm-md-CUST_1)#ma-name ma_5 vlan-id 10 priority 3
4. Set the time interval between successive Continuity Check Messages. The default is
10-seconds.
Brocade(config-cfm-md-CUST_1-ma-ma_5)#ccm-interval 10-second
5. Configure a MEP on port 1/1 and vlan 10.
Brocade(config-cfm-md-CUST_1-ma-ma_5)#mep 1 down vlan 10 port ethe 1/1
6. Configure a remote-mep.
Brocade(config-cfm-md-CUST_1-ma-ma_5)#remote-mep 2 to 2
7. Continue the configuration for other CE devices as needed.
Configuration for PE Devices:
Configuring PEB-1
Tag-type configuration
Assume CVLAN tag-type is 0x8100 and S-VLAN tag-type is 0x900.
Brocade(config)#tag-type 8100 eth 1/1
Brocade(config)#tag-type 8100 eth 1/2
Brocade(config)#tag-type 9100 eth 1/3
VPLS local configuration:
Assume CE-1 is connected to PEB-1 port 1/1 on VLAN 10 and CE-2 is connected to PEB-2 port 1/2
on VLAN 20 and PEB-1 is connected to BEB-1 on port 1/3 VLAN 30.
Brocade(config)#router mpls
Brocade(config-mpls)#vpls PB-VPLS 20
Brocade(config-mpls-vpls-PB-VPLS)#pbb
Brocade(config-mpls-vpls-PB-VPLS-pbb)#exit
Brocade(config-mpls-vpls-PB-VPLS)#
Brocade(config-mpls-vpls-PB-VPLS)#vlan 10
Brocade(config-mpls-vpls-PB-VPLS-vlan-10)#tagged eth 1/1
Brocade(config-mpls-vpls-PB-VPLS-vlan-10)#
Brocade(config-mpls-vpls-PB-VPLS-vlan-10)#vlan 20
Brocade(config-mpls-vpls-PB-VPLS-vlan-20)#tagged eth 1/2
Brocade(config-mpls-vpls-PB-VPLS-vlan-20)#
Brocade(config-mpls-vpls-PB-VPLS-vlan-20)#vlan 30
Brocade(config-mpls-vpls-PB-VPLS-vlan-30)#tagged eth 1/3
CFM configuration:
If the VPLS local configuration is not done prior to configuring maintenance association. The MA
configuration is not allowed. PEB-1 will work as a MIP.
Syntax: ma-name MANAME {vlan-id vlan-id | vpls-id vpls-id | pbb-vpls vpls-id | [vll
[vll-name]|[vll-id]|vll-local [vll-name] } priority priority
1. Enable CFM using the cfm-enable command.
Brocade(config)#cfm-enable