Brocade Multi-Service IronWare Switching Configuration Guide (Supporting R05.6.00) User Manual
Page 961
![background image](/manuals/361635/961/background.png)
Multi-Service IronWare Switching Configuration Guide
931
53-1003036-02
Configuring BFD for the specified protocol
25
TABLE 129
Display of BFD neighbor detail information
This field...
Displays...
Total number of Neighbor entries
Total number of BFD sessions.
NeighborAddress
IPv4 or IPv6 address of the remote peer.
State
The current state of the BFD session:
Up
Down
A.DOWN – The administrative down state.
INIT – The Init state.
UNKNOWN – The current state is unknown.
Interface
The logical port on which the peer is known.
Holddown
The interval in microseconds after which the session will transition to
the down state if no message is received.
Interval
The interval in microseconds at which the local device sends BFD
messages to the remote peer.
R/H
Heard from remote, values: Y or N where Y stand for Yes and N stand for
No; H- Single hop/Multihop Values are S and M where S stand for Single
Hop and M stand for MultiHop.
Registered Protocols
Specifies which protocols are registered to use BFD on this port.
Local:
Disc
Value of the local discriminator field in the BFD Control Message as
used by the local device in the last message sent.
Diag
Value of the diagnostic field in the BFD Control Message as used by the
local device in the last message sent.
Demand
Value of the demand bit in the BFD Control Message as used by the local
device in the last message sent.
Poll
Value of the poll bit in the BFD Control Message as used by the local
device in the last message sent.
MinTxInterval
The interval in microseconds during which the device will send a BFD
message from this local neighbor port to the peer.
MinRxInterval
The interval in microseconds that the neighbor device waits to receive a
BFD message from the peer on this local port.
Multiplier
The number of times the neighbor device will wait for the MinRxInterval
time on this port before it determines the peer device is non-operational.
Remote:
Disc
Value of the local discriminator field in the BFD Control Message as
received in the last message sent by the remote peer.
Diag
Value of the diagnostic field in the BFD Control Message as received in
the last message sent by the remote peer.
Demand
Value of the demand bit in the BFD Control Message as received in the
last message sent by the remote peer.
Poll
Value of the poll bit in the BFD Control Message as received in the last
message sent by the remote peer.
MinTxInterval
The interval in milliseconds during which the device will send a BFD
message from the remote neighbor port to the peer.