Multi-Service IronWare Switching Configuration Guide

261

53-1003036-02

Point to Point PBB

10

Point to Point PBB

Point to Point PBB (P2P PBB) provides the ability to turn off MAC address learning on a per service
instance basis (ISID). This provides support for point-to-point services, such as EVPL, which do not
require MAC address learning. Point to Point PBB is designed to flood the traffic to a specific
remote BEB in the core PBB network, instead of flooding across all the BEBs.

Limitations

When P2P PBB is enabled, the MACs learned on S-VLANs are duplicated in the new flood domain.
This will reduce the maximum number of supported MACs from 131072 VPLS MACs to 65536 VPLS
MACs.

Configuring Point to Point PBB

Use the p2p-mac command to enable this feature. Since the P2P PBB feature is specific to a
service instance it has to be executed for each ISID.

Brocade(config)#esi A-isid encapsulation isid

Brocade(config-esi-A-isid)#isid 18001

Brocade(config-esi-A-isid-isid-18001)#p2p-mac 001b.edb4.5ac1

Syntax: [no] p2p-mac mac-addr

The mac-addr parameter requires the MAC address of the remote BEB.

Use the [no] parameter to disable this feature.

Show commands

Use the show flood-domain command to display the extra flood-domain (shadow flood domain).
This extra flood domain information is only shown for P2P PBB instances.

Brocade# show flood-domain

FDID

Type NumMem VLAN Owner VLAN Owner ESI

----

---- --------- ---------- ---------

4357

PBB 2

1234

i-isid

4358

B_VLAN 1

500

b-vlan

4359

S_LOOP 1

100

s-vlan

4360

S_FWD 2

100

s-vlan

4369, 4370 PBB 1

2345

A-isid

You can use the show flood-domain fd_id to filter the flood domain. The show flood-domain
shadow_fd_id command can also be used to show the identical information.

Brocade#show flood-domain 4369

Brocade#show flood-domain 4370

FDID

Type NumMem VLAN Owner VLAN Owner ESI

----

---- ---------- ---------- ---------

4369, 4370 PBB 1

2345 A-isid