Brocade# show cfm
Domain: D1
Index: 1
Level: 3
Maintenance association: MA
Ma Index: 1
CCM interval: 10000 ms
PBB-VPLS ID: 100
Priority: 3
MEP Direction MAC
PORT PORT-STATUS-TLV
==== ======== ========= ===== ==============
1
UP
0012.f2f7.3900 ethe 1/1 N
MIP VLAN/VC Port
Level
MAC
==== ======== =====
=====
==========
200
1/1
3
0012.f2f7.3901
Brocade# show cfm connectivity
Domain: D1 Index: 1
Level: 3
Maintenance association: MA
MA Index: 1
CCM interval: 10000 ms
PBB-VPLS ID: 100
Priority: 3
RMEP
MAC
VLAN/ISID AGE
PORT
SLOTS STATE
====
=====
=======
====== ======= ==== =========
10
0012.f2f7.3860 200
73460
1/2
1
OK
802.1ag for BVLAN
BVLAN functionality is supported by the use of regular VLANs only.
802.1ag for ISID
PBB-VPLS functionality supports IB-tagged end-points. 802.1ag for ISID is supported in a similar
manner as it is supported for CVLAN and SVLAN end-points for local-VPLS. It requires the creation
of a new MA for PBB-VPLS.
Brocade(config- dot1ag -DONAME)# ma-name MANAME pbb-vpls 10 priority 4
Syntax: ma-name MANAME {vlan-id vlan-id | vpls-id vpls-id | pbb-vpls vpls-id | [vll
[vll-name]|[vll-id]|vll-local [vll-name] } priority priority mep mep-id [ up | down ] [vlan
vlan-id ISID isid port port-id | vlan vlan-id port port-id | port port-id ]
•
Both down MEP and UP MEP configuration is accepted for ISID.
•
UP MEP for ISID will transmit CCM packets out ONLY on the BVLAN ports carrying the same
ISID.
•
MIP functionality is not supported for ISID.
•
802.1ag sub-second-timer functionality for ISID is supported.
•
802.1ag functionality for ISID during switchover is supported.
•
802.1ag functionality for ISID during hitless upgrade is not supported.
•
802.1ag functionality for ISID is supported where IB-tagged end-points are LAG.