beautypg.com

Manual switch – Brocade Multi-Service IronWare Switching Configuration Guide (Supporting R05.6.00) User Manual

Page 551

background image

Multi-Service IronWare Switching Configuration Guide

521

53-1003036-02

Manual switch

15

Figure 135

shows a simple Ethernet ring topology before a failure. This diagram shows dual-end

blocking enabled (thick line) between ERNs one (RPL node) and 6 (RPL owner). ERNs 3, 2, 4, and 5
are non-RPL nodes.

FIGURE 135

ERP topology

Figure 136

shows the same Ethernet ring topology after a failure at the forwarding port of ERN 4

when a signal fail triggered, and ring protection was needed. ERN 6 unblocked the RPL port and
the RPL node changed the blocking port to the forwarding state.

FIGURE 136

ERP topology in a Protected state

Manual switch

In the absence of a failure, an operator-initiated manual switch (MS) moves the blocking role of the
RPL by blocking a different ring link and initiates the node sending a R-APS (MS) to inform the RPL
owner to unblock the RPL. This can occur if no higher priority request exists in the ring. See

Figure 137

. The thick line between ERNs 1 and 2 indicate that dual-end blocking is enabled.

FIGURE 137

Manual Switch example