Yaskawa AC Drive-P1000 Industrial Fan User Manual

Page 551

background image

No.

Name

User

Setting

d3-04

Jump Frequency Width

d4-01

Frequency Reference Hold Function Selection

d4-03

Frequency Reference Bias Step (Up/Down 2)

d4-04

Frequency Reference Bias Accel/Decel (Up/Down

2)

d4-05

Frequency Reference Bias Operation Mode

Selection (Up/Down 2)

d4-06

Frequency Reference Bias (Up/Down 2)

d4-07

Analog Frequency Reference Fluctuation Limit

(Up/Down 2)

d4-08

Frequency Reference Bias Upper Limit (Up/Down

2)

d4-09

Frequency Reference Bias Lower Limit (Up/Down

2)

d4-10

Up/Down Frequency Reference Limit Selection

d6-01

Field Weakening Level

d6-02

Field Weakening Frequency Limit

E1-01

Input Voltage Setting

E1-03

V/f Pattern Selection

E1-04

Maximum Output Frequency

E1-05

Maximum Voltage

E1-06

Base Frequency

E1-07

Middle Output Frequency

E1-08

Middle Output Frequency Voltage

E1-09

Minimum Output Frequency

E1-10

Minimum Output Frequency Voltage

E1-11

Middle Output Frequency 2

E1-12

Middle Output Frequency Voltage 2

E1-13

Base Voltage

E2-01

Motor Rated Current

E2-02

Motor Rated Slip

E2-03

Motor No-Load Current

E2-04

Number of Motor Poles

E2-05

Motor Line-to-Line Resistance

E2-06

Motor Leakage Inductance

E2-10

Motor Iron Loss for Torque Compensation

E2-11

Motor Rated Power

F4-01

Terminal V1 Monitor Selection

F4-02

Terminal V1 Monitor Gain

F4-03

Terminal V2 Monitor Selection

F4-04

Terminal V2 Monitor Gain

F4-05

Terminal V1 Monitor Bias

F4-06

Terminal V2 Monitor Bias

F4-07

Terminal V1 Signal Level

F4-08

Terminal V2 Signal Level

No.

Name

User

Setting

F6-01

Communications Error Operation Selection

F6-02

External Fault from Comm. Option Detection

Selection

F6-03

External Fault from Comm. Option Operation

Selection

F6-04

bUS Error Detection Time

F6-07

Multi-Step Speed Enable/Disable Selection when

NefRef/ComRef is Selected

F6-08

Reset Communication Parameters

F6-10

CC-Link Node Address

F6-11

CC-Link Communications Speed

F6-14

CC-Link bUS Error Auto Reset

F6-20

MECHATROLINK Station Address

F6-21

MECHATROLINK Frame Size

F6-22

MECHATROLINK Link Speed

F6-23

MECHATROLINK Monitor Selection (E)

F6-24

MECHATROLINK Monitor Selection (F)

F6-25

Operation Selection at Watchdog Timer Error (E5)

F6-26

MECHATROLINK bUS Errors Detected

F6-30

PROFIBUS-DP Node Address

F6-31

PROFIBUS-DP Clear Mode Selection

F6-32

PROFIBUS-DP Data Format Selection

F6-35

CANopen Node ID Selection

F6-36

CANopen Communication Speed

F6-50

DeviceNet MAC Address

F6-51

DeviceNet Communication Speed

F6-52

DeviceNet PCA Setting

F6-53

DeviceNet PPA Setting

F6-54

DeviceNet Idle Mode Fault Detection

F6-55

DeviceNet Baud Rate Monitor

F6-56

DeviceNet Speed Scaling

F6-57

DeviceNet Current Scaling

F6-58

DeviceNet Torque Scaling

F6-59

DeviceNet Power Scaling

F6-60

DeviceNet Voltage Scaling

F6-61

DeviceNet Time Scaling

F6-62

DeviceNet Heartbeat Interval

F6-63

DeviceNet Network MAC ID

H1-01

Multi-Function Digital Input Terminal S1 Function

Selection

H1-02

Multi-Function Digital Input Terminal S2 Function

Selection

H1-03

Multi-Function Digital Input Terminal S3 Function

Selection

H1-04

Multi-Function Digital Input Terminal S4 Function

Selection

H1-05

Multi-Function Digital Input Terminal S5 Function

Selection

H1-06

Multi-Function Digital Input Terminal S6 Function

Selection

H1-07

Multi-Function Digital Input Terminal S7 Function

Selection

E.3 User Setting Table

YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual

551

E

Quick Reference Sheet