beautypg.com

B.15 defaults by drive model – Yaskawa AC Drive-P1000 Industrial Fan User Manual

Page 478

background image

No.

Name

Unit

Model CIMR-Po

5A0003

5A0004

5A0006

5A0009

5A0011

o2-04

Drive Model Selection

Hex.

C3

C4

C5

C7

E2-11

Motor Rated Power

kW

(HP)

1.5

(2)

2.2

(3)

3.7

(5)

5.5

(7.5)

7.5

(10)

L2-04

Momentary Power Loss Voltage Recovery

Time

s

0.5

0.5

0.6

0.7

0.8

L3-24

Motor Acceleration Time for Inertia

Calculations

s

0.166

0.145

0.154

0.168

0.175

L8-02

Overheat Alarm Level

°C

110

110

110

110

115

L8-35

Installation Method Selection

2

2

2

2

2

L8-38

Carrier Frequency Reduction Selection

2

2

2

2

2

n1-03

Hunting Prevention Time Constant

ms

10

10

10

10

10

B.15 Defaults by Drive Model

478

YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual

This manual is related to the following products: