C3: Slip Compensation

The Slip Compensation function improves the speed accuracy of an induction motor. By adjusting the output frequency in

accordance with the motor load, it compensates the slip and makes the motor speed equal to the frequency reference.

Note:

Perform Auto-Tuning and make sure that the motor rated current (E2-01), the motor rated slip (E2-02), and the no-load current (E2-03)

have all been set properly before making any adjustments to slip compensation parameters.

n

C3-01: Slip Compensation Gain

Sets the gain for the motor slip compensation function. Although this parameter rarely needs to be changed, adjustments may

be necessary under the following circumstances:
• Increase the setting if the motor at constant speed is slower than the frequency reference.
• Decrease the setting if the motor at constant speed is faster than the frequency reference.

No.

Parameter Name

Setting Range

Default

C3-01

Slip Compensation Gain

0.0 to 2.5

0.0

n

C3-02: Slip Compensation Primary Delay Time

Adjusts the filter on the output side of the slip compensation function. Although this parameter rarely needs to be changed,

adjustments may be necessary in the following situations:
• Decrease the setting when the slip compensation response is too slow.
• Increase this setting when speed is unstable.

No.

Parameter Name

Setting Range

Default

C3-02

Slip Compensation Primary Delay Time

0 to 10000 ms

2000 ms

n

C3-03: Slip Compensation Limit

Sets the upper limit for the slip compensation function as a percentage of the motor rated slip (E2-02).

No.

Parameter Name

Setting Range

Default

C3-03

Slip Compensation Limit

0 to 250%

200%

The slip compensation limit is constant throughout the constant torque range (frequency reference ≤ E1-06). In the constant

power range (frequency reference ≥ E1-06), it is increased based on C3-03 and the output frequency as shown in the following

diagram.

E1-04
E1-06 × C3-03

C3-03

E1-04

Maximum

Frequency

E1-06

Base

Frequency

Output Frequency

Figure 5.24 Slip Compensation Limit

n

C3-04: Slip Compensation Selection during Regeneration

Enables or disables slip compensation during regenerative operation. When slip compensation during regeneration has been

activated and a regenerative load is applied, it might be necessary to use a dynamic braking option (braking resistor, braking

resistor unit, or braking unit).
This function does not operate when the output frequency is too low, regardless of whether it has been enabled.

No.

Parameter Name

Setting Range

Default

C3-04

Slip Compensation Selection during Regeneration

0 to 2

0

Setting 0: Disabled

Slip compensation is not provided. Depending on the load and mode of operation, the actual motor speed will be lower or

higher than the frequency reference.