beautypg.com

D.3 ul and csa standards – Yaskawa AC Drive-P1000 Industrial Fan User Manual

Page 530

background image

Drive Model

Terminal

Recomm. Gauge

AWG, kcmil

Wire Range

AWG, kcmil

Screw

Size

Tightening Torque

N·m (lb.in.)

2A0211

R/L1, S/L2, T/L3

1/0 × 2P

1/0 to 2/0

M10

18 to 23

(159 to 204)

U/T1, V/T2, W/T3

1/0 × 2P

1/0 to 2/0

⊖, ⊕1

1 to 4/0

⊕3

1/0 to 4/0

4

4 to 1/0

2A0250

R/L1, S/L2, T/L3

3/0 × 2P

3/0 to 300

M12

32 to 40

(283 to 354)

U/T1, V/T2, W/T3

3/0 × 2P

3/0 to 300

⊖, ⊕1

3/0 to 300

⊕3

2 to 300

M10

18 to 23

(159 to 204)

3

3 to 300

M12

32 to 40

(283 to 354)

2A0312

R/L1, S/L2, T/L3

4/0 × 2P

3/0 to 300

M12

32 to 40

(283 to 354)

U/T1, V/T2, W/T3

3/0 × 2P

3/0 to 300

⊖, ⊕1

3/0 to 300

⊕3

3/0 to 300

M10

18 to 23

(159 to 204)

2

2 to 300

M12

32 to 40

(283 to 354)

2A0360

R/L1, S/L2, T/L3

250 × 2P

4/0 to 600

M12

32 to 40

(283 to 354)

U/T1, V/T2, W/T3

4/0 × 2P

4/0 to 600

⊖, ⊕1

250 to 600

⊕3

3/0 to 600

M10

18 to 23

(159 to 204)

1

1 to 350

M12

32 to 40

(283 to 354)

2A0415

R/L1, S/L2, T/L3

350 × 2P

250 to 600

M12

32 to 40

(283 to 354)

U/T1, V/T2, W/T3

300 × 2P

300 to 600

⊖, ⊕1

300 to 600

⊕3

3/0 to 600

M10

18 to 23

(159 to 204)

1

1 to 350

M12

32 to 40

(283 to 354)

<1> Install a GFCI when using this wire gauge in accordance with IEC/EN 61800-5-1.
<2> Install a GFCI, or use 10 mm

2

(AWG 8) copper wire when using this wire gauge in accordance with IEC/EN 61800-5-1.

D.3 UL and CSA Standards

530

YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual

This manual is related to the following products: