No.

(Addr.

Hex)

Name

Description

Values

Page

L6-04

(4A4)

Torque Detection

Selection 2

0: Disabled

1: oL4 detection only active during speed agree, operation continues after

detection

2: oL4 detection always active during run, operation continues after detection

3: oL4 detection only active during speed agree, output shuts down on an oL4

fault

4: oL4 detection always active during run, output shuts down on an oL4 fault

5: UL4 detection only active during speed agree, operation continues after

detection

6: UL4 detection always active during run, operation continues after detection

7: UL4 detection only active during speed agree, output shuts down on an oL4

fault

8: UL4 detection always active during run, output shuts down on an oL4 fault

Default: 0

Range: 0 to 8

255

L6-05

(4A5)

Torque Detection

Level 2

Sets the overtorque and undertorque detection level.

Default: 150%

Min.: 0

Max.: 300

256

L6-06

(4A6)

Torque Detection

Time 2

Sets the time an overtorque or undertorque condition must exist to trigger

torque detection 2.

Default: 0.1 s

Min.: 0.0

Max.: 10.0

256

L6-13

(62E)

Motor Underload Protection

Selection

Sets the motor underload protection (UL6) based on motor load.

0: Base frequency enable

1: Max frequency enable

Default: 0

Range: 0, 1

255

L6-14

(62F)

Motor Underload Protection

Level at Minimum

Frequency

Sets the UL6 detection level at minimum frequency by percentage of drive

rated current.

Default: 15%

Min.: 0

Max.: 300

255

u

L8: Drive Protection

No.

(Addr.

Hex)

Name

Description

Values

Page

L8-01

(4AD)

Internal Dynamic Braking

Resistor Protection

Selection (ERF type)

0: Resistor overheat protection disabled

1: Resistor overheat protection enabled

Default: 0

Range: 0, 1

256

L8-02

(4AE)

Overheat Alarm Level

An overheat alarm occurs when heatsink temperature exceeds the L8-02 level. Default:

<1>

Min.: 50 °C

Max.: 150 °C

257

L8-03

(4AF)

Overheat Pre-Alarm

Operation Selection

0: Ramp to stop. A fault is triggered.

1: Coast to stop. A fault is triggered.

2: Fast Stop. Decelerate to stop using the deceleration time in C1-09. A fault

is triggered.

3: Continue operation. An alarm is triggered.

4: Continue operation at reduced speed as set in L8-19.

Default: 3

Range: 0 to 4

257

L8-05

(4B1)

Input Phase Loss Protection

Selection

Selects the detection of input current phase loss, power supply voltage

imbalance, or main circuit electrolytic capacitor deterioration.

0: Disabled

1: Enabled

Default: 1

Range: 0, 1

258

L8-07

(4B3)

Output Phase Loss

Protection Selection

0: Disabled

1: Enabled (triggered by a single phase loss)

2: Enabled (triggered when two phases are lost)

Default: 1

Range: 0 to 2

258

L8-09

(4B5)

Output Ground Fault

Detection Selection

0: Disabled

1: Enabled

Default: 1

Range: 0, 1

259

L8-10

(4B6)

Heatsink Cooling Fan

Operation Selection

0: During run only. Fan operates only during run for L8-11 seconds after stop.

1: Fan always on. Cooling fan operates whenever the drive is powered up.

Default: 0

Range: 0, 1

259

L8-11

(4B7)

Heatsink Cooling Fan Off

Delay Time

Sets a delay time to shut off the cooling fan after the Run command is removed

when L8-10 = 0.

Default: 60 s

Min.: 0

Max.: 300

259

L8-12

(4B8)

Ambient Temperature

Setting

Enter the ambient temperature. This value adjusts the oL2 detection level.

Default: 40 °C

Min.: -10

Max.: 50

259

L8-15

(4BB)

oL2 Characteristics

Selection at Low Speeds

0: No oL2 level reduction below 6 Hz.

1: oL2 level is reduced linearly below 6 Hz. It is halved at 0 Hz.

Default: 1

Range: 0, 1

259

L8-18

(4BE)

Software Current Limit

Selection

0: Disabled

1: Enabled

Default: 0

Range: 0, 1

260

B.8 L: Protection Function

446

YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual