B.14 V/f Pattern Default Values

The following tables show the V/f pattern setting default values depending on the V/f pattern selection (E1-03).

Table B.3 E1-03 V/f Pattern Settings for Drive Capacity: 2A0004 to 2A0021, 4A0002 to 4A0011, and 5A0003 to 5A0009

No.

Unit

V/f Control

E1-03

-

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

E1-04

Hz

50.0

60.0

60.0

72.0

50.0

50.0

60.0

60.0

50.0

50.0

60.0

60.0

90.0

120.0

180.0

60.0

E1-05

<2>

V

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

230.0

E1-06

Hz

50.0

60.0

50.0

60.0

50.0

50.0

60.0

60.0

50.0

50.0

60.0

60.0

60.0

60.0

60.0

60.0

E1-07

Hz

2.5

3.0

3.0

3.0

25.0

25.0

30.0

30.0

2.5

2.5

3.0

3.0

3.0

3.0

3.0

3.0

E1-08

<2>

V

15.0

15.0

15.0

15.0

35.0

50.0

35.0

50.0

19.0

24.0

19.0

24.0

15.0

15.0

15.0

17.3

E1-09

Hz

1.3

1.5

1.5

1.5

1.3

1.3

1.5

1.5

1.3

1.3

1.5

1.5

1.5

1.5

1.5

1.5

E1-10

<2>

V

9.0

9.0

9.0

9.0

8.0

9.0

8.0

9.0

11.0

13.0

11.0

15.0

9.0

9.0

9.0

10.2

<2> Values shown here are specific to 200 V class drives. Double the value for 400 V class drives. Multiply the value by 2.875 for 600 V class drives.

Table B.4 E1-03 V/f Pattern Settings for Drive Capacity: 2A0030 to 2A0211, 4A0018 to 4A0103, and 5A0011 to 5A0077

No.

Unit

V/f Control

E1-03

-

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

<1>

E1-04

Hz

50.0

60.0

60.0

72.0

50.0

50.0

60.0

60.0

50.0

50.0

60.0

60.0

90.0

120.0

180.0

60.0

E1-05

<2>

V

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

230.0

E1-06

Hz

50.0

60.0

50.0

60.0

50.0

50.0

60.0

60.0

50.0

50.0

60.0

60.0

60.0

60.0

60.0

60.0

E1-07

Hz

2.5

3.0

3.0

3.0

25.0

25.0

30.0

30.0

2.5

2.5

3.0

3.0

3.0

3.0

3.0

3.0

E1-08

<2>

V

14.0

14.0

14.0

14.0

35.0

50.0

35.0

50.0

18.0

23.0

18.0

23.0

14.0

14.0

14.0

16.1

E1-09

Hz

1.3

1.5

1.5

1.5

1.3

1.3

1.5

1.5

1.3

1.3

1.5

1.5

1.5

1.5

1.5

1.5

E1-10

<2>

V

7.0

7.0

7.0

7.0

6.0

7.0

6.0

7.0

9.0

11.0

9.0

13.0

7.0

7.0

7.0

8.1

<1> This value determines the default values for E1-04 through E1-10.
<2> Values shown here are specific to 200 V class drives. Double the value for 400 V class drives. Multiply the value by 2.875 for 600 V class drives.

Table B.5 E1-03 V/f Pattern Settings for Drive Capacity: 2A0250 to 2A0415, 4A0139 to 4A1200, and 5A0099 to 5A0242

No.

Unit

V/f Control

E1-03

-

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

<1>

E1-04

Hz

50.0

60.0

60.0

72.0

50.0

50.0

60.0

60.0

50.0

50.0

60.0

60.0

90.0

120.0

180.0

60.0

E1-05

<2>

V

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

200.0

230.0

E1-06

Hz

50.0

60.0

50.0

60.0

50.0

50.0

60.0

60.0

50.0

50.0

60.0

60.0

60.0

60.0

60.0

60.0

E1-07

Hz

2.5

3.0

3.0

3.0

25.0

25.0

30.0

30.0

2.5

2.5

3.0

3.0

3.0

3.0

3.0

3.0

E1-08

<2>

V

12.0

12.0

12.0

12.0

35.0

50.0

35.0

50.0

15.0

20.0

15.0

20.0

12.0

12.0

12.0

13.8

E1-09

Hz

1.3

1.5

1.5

1.5

1.3

1.3

1.5

1.5

1.3

1.3

1.5

1.5

1.5

1.5

1.5

1.5

E1-10

<2>

V

6.0

6.0

6.0

6.0

5.0

6.0

5.0

6.0

7.0

9.0

7.0

11.0

6.0

6.0

6.0

6.9

<1> This value determines the default values for E1-04 through E1-10 .
<2> Values shown here are specific to 200 V class drives. Double the value for 400 V class drives. Multiply the value by 2.875 for 600 V class drives.

B.14 V/f Pattern Default Values

YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual

465

B

Parameter List

This manual is related to the following products: