beautypg.com

2 mechanical installation – Yaskawa AC Drive-P1000 Industrial Fan User Manual

Page 54

background image

Internal/Flush-Mount

An internal flush-mount requires an installation support set that must be purchased separately. Contact a Yaskawa

representative to order an installation support set and mounting hardware.

Figure 2.13

illustrates how to attach the Installation

Support Set A.

1.

Cut an opening in the enclosure panel for the digital operator as shown in

Figure 2.14

.

2.

Mount the digital operator to the installation support.

3.

Mount the installation support set and digital operator to the enclosure panel.

Enclosure panel

Unit: mm

Digital Operator

Installation Support Set A

M4 × 10
Phillips truss head screw × 4
(for panel widths between 1 and 1.6)

M3

× 6

Phillips recessed
pan head machine screw × 2

Figure 2.13 Internal/Flush Mount Installation

Note:

Use a gasket between the enclosure panel and the digital operator in environments with a significant amount of dust or other airborne debris.

120

45

59

+0.5

0

89

+0.5 0

Unit : mm

Figure 2.14 Panel Cut-Out Dimensions (Internal/Flush-Mount Installation)

2.2 Mechanical Installation

54

YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual

This manual is related to the following products: