beautypg.com

Alarm and error displays, Faults – Yaskawa AC Drive-P1000 Industrial Fan User Manual

Page 293

background image

u

Alarm and Error Displays

n

Faults

Table 6.4

gives an overview of possible fault codes. Conditions such as overvoltages can trip faults and alarms. It is important

to distinguish between faults and alarms to determine the proper corrective actions.
When the drive detects a fault, the ALM indicator LED lights, the fault code appears on the digital operator, and the fault

contact MA-MB-MC triggers. An alarm is present if the ALM LED blinks and the fault code on the digital operator flashes.

Refer to Minor Faults and Alarms on page 294

for a list of alarm codes.

Table 6.4 Fault Displays

Digital

Operator

Display

Name

Page

bAT

Digital Operator Battery Voltage Low

296

boL

Braking Transistor Overload Fault

296

bUS

Option Communication Error

296

CE

MEMOBUS/Modbus Communication Error

296

CPF11 to

CPF14

<1> <3>

Control Circuit Error

296

CPF16 to

CPF19

<1> <3>

Control Circuit Error

296

CPF02

A/D Conversion Error

297

CPF03

Control Board Connection Error

297

CPF06

<3>

EEPROM Memory Data Error

297

CPF07,

CPF08

Terminal Board Connection Error

297

CPF20,

CPF21

<2>

Control Circuit Error

297

CPF22

Hybrid IC Error

297

CPF23

Control Board Connection Error

298

CPF24

<3>

Drive Unit Signal Fault

298

CPF25

Terminal Board Not Connected

298

CPF26 to

CPF35,

CPF40 to

CPF43

<4>

Control Circuit Error

298

E5

SI-T3 Watchdog Timer Error

298

EF0

Option Card External Fault

298

EF1 to EF8 External Fault

(input terminal S1 to S8)

298

Err

EEPROM Write Error

299

FAn

Internal Fan Fault

298

FbH

Excessive PID Feedback

299

FbL

PID Feedback Loss

300

GF

Ground Fault

300

LF

Output Phase Loss

300

LF3

<4>

Power Unit Output Phase Loss 3

300

nSE

Node Setup Error

300

oC

Overcurrent

301

oFA00

<3>

Option Card Connection Error

(CN5-A)

301

Digital

Operator

Display

Name

Page

oFA01

Option Card Fault (CN5-A)

302

oFA03 to

oFA06

Option Card Error

(CN5-A)

302

oFA10,

oFA11

Option Card Error

(CN5-A)

302

oFA12 to

oFA17

Option Card Connection Error

(CN5-A)

302

oFA30 to

oFA43

Comm Option Card Connection Error

(CN5-A)

302

oFb00

<3>

Option Card Connection Error

(CN5-B)

302

oFb01

Option Card Fault (CN5-B)

302

oFb02

Option Card Fault (CN5-B)

302

oFb03,

oFb11

Option Card Error (CN5-B)

302

oFb12 to

oFb17

Option Card Connection Error

(CN5-B)

302

oFC00

<3>

Option Card Connection Error

(CN5-C)

303

oFC01

Option Card Fault (CN5-C)

303

oFC02

Option Card Fault (CN5-C)

303

oFC03,

oFC11

Option Card Error (CN5-C)

303

oFC12 to

oFC17

Option Card Connection Error

(CN5-C)

303

oFC50 to

oFC55

Option Card Error (CN5-C)

303

oH

Heatsink Overheat

303

oH1

Heatsink Overheat

304

oH4

Motor Overheat Fault (PTC input)

304

oH5

<4>

Motor Overheat (NTC Input)

304

oL1

Motor Overload

304

oL2

Drive Overload

305

oL3

Overtorque Detection 1

305

oL4

Overtorque Detection 2

305

oL7

High Slip Braking oL

305

oPr

Operator Connection Fault

305

ov

Overvoltage

306

PF

Input Phase Loss

306

rF

Braking Resistor Fault

307

rH

Dynamic Braking Resistor

307

rr

Dynamic Braking Transistor

307

SC

IGBT Short Circuit or Ground Fault

307

6.3 Drive Alarms, Faults, and Errors

YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual

293

6

Troubleshooting

This manual is related to the following products: