beautypg.com

Yaskawa AC Drive-P1000 Industrial Fan User Manual

Page 302

background image

The option card installed into port CN5-A is

incompatible with the drive

Check if the drive supports the option card to be installed. Contact Yaskawa for assistance.

Digital Operator Display

Fault Name

oFA01

Option Card Fault at Option Port CN5-A
Option not properly connected

Cause

Possible Solution

The option card connection to port CN5-A is

faulty

• Turn off the power and reconnect the option card.
• Check if the option card is properly plugged into the option port. Make sure the card is fixed properly.
• If the option is not a communication option card, try to use the card in a different option port. If the

option card works properly in a different option port, CN5-A is damaged, and the drive requires

replacement. If the error persists (oFb01 or oFC01 occur), replace the option card.

Digital Operator Display

Fault Name

to

oFA03 to oFA06

Option Card Error Occurred at Option Port CN5-A

,

oFA10, oFA11

to

oFA12 to oFA17

Option Card Connection Error (CN5-A)

to

oFA30 to oFA43

Communication Option Card Connection Error (CN5-A)

Cause

Possible Solution

Option card or hardware is damaged

• Cycle power to the drive.
• If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa

representative for instructions on replacing the control board.

Digital Operator Display

Fault Name

oFb00

Option Card Fault at Option Port CN5-B
Option compatibility error

Cause

Possible Solution

The option card installed into port CN5-B is

incompatible with the drive

Make sure the drive supports the option card to be installed. Contact Yaskawa for assistance.

A communication option card has been

installed in option port CN5-B

Communication option cards are only supported by option port CN5-A. It is not possible to install more

than one communication option.

Digital Operator Display

Fault Name

oFb01

Option Card Fault at Option Port CN5-B
Option not properly connected

Cause

Possible Solution

The option card connection to port CN5-B is

faulty

• Turn off the power and reconnect the option card.
• Check if the option card is properly plugged into the option port. Make sure the card is fixed properly.
• Try to use the card in a different option port. If the option card works properly in a different option

port, CN5-B is damaged, and the drive requires replacement. If the error persists (oFA01 or oFC01

occur), replace the option card.

Digital Operator Display

Fault Name

oFb02

Option Card Fault at Option Port CN5-B
Same type of option card is currently connected

Cause

Possible Solution

An option card of the same type is already

installed in option port CN5-A

Only one of each option card type can only be installed simultaneously. Make sure only one type of option

card is connected.

An input option card is already installed in

option port CN5-A

Install a communication option. More than one of the same type of card cannot be installed simultaneously.

Digital Operator Display

Fault Name

to

oFb03 to oFb11

Option card error occurred at Option Port CN5-B

to

oFb12 to oFb17

Cause

Possible Solution

Option card or hardware is damaged

• Cycle power to the drive.
• If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa