Register No.
Contents
00B0H
Option Code Connected to
CN5-A
Register contains ASCII code of the option card.
AO-A3 = 0004H
Communication Option: Register contains ASCII code of first and third digit of the option card
type number.
Example: Register value is 5343H for “SC” if an SI-C3 option card is installed.
00B1H
Reserved
00B2H
Option Code Connected to CN5-B
00B3H
Option Code Connected to CN5-C
00B4H
Reserved
00B5H
Frequency Reference After
Soft-starter (U1-16)
r/min units
<4>
00B6H
0.01% units
00B7H
Frequency Reference
r/min
<4>
00B8H
0.01% units
00B9H to 00BEH
Reserved
00BFH
Lists the last two digits of operation error code oPEoo.
00C0H
Fault Contents 3
bit 1
Undervoltage (Uv1)
bit 2
Control Power Supply Undervoltage (Uv2)
bit 3
Soft Charge Circuit Fault (Uv3)
bit 4
IGBT Short Circuit (SC)
bit 5
Ground Fault (GF)
bit 6
Overcurrent (oC)
bit 7
Overvoltage (ov)
bit 8
Heatsink Overheat (oH)
bit 9
Heatsink Overheat (oH1)
bit A
Motor Overload (oL1)
bit B
Drive Overload (oL2)
bit C
Overtorque Detection 1 (oL3)
bit D
Overtorque Detection 2 (oL4)
bit E
Dynamic Braking Transistor Fault (rr)
bit F
Braking Resistor Overheat (rH)
00C1H
Fault Contents 4
bit 0
External Fault at input terminal S3 (EF3)
bit 1
External Fault at input terminal S4 (EF4)
bit 2
External Fault at input terminal S5 (EF5)
bit 3
External Fault at input terminal S6 (EF6)
bit 4
External Fault at input terminal S7 (EF7)
bit 5
External Fault at input terminal S8 (EF8)
bit 6
Cooling Fan Error (FAn)
bit 7 to 9
Reserved
bit A
Input Phase Loss (PF)
bit B
Output Phase Loss (LF)
bit C
Motor Overheat (PTC input) (oH3)
bit D
Digital Operator Connection Fault (oPr)
bit E
EEPROM Write Error (Err)
bit F
Motor Overheat Fault (PTC input) (oH4)
C.9 MEMOBUS/Modbus Data Table
YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual
503
C