beautypg.com

Navigating the drive and programming modes, Drive mode details – Yaskawa AC Drive-P1000 Industrial Fan User Manual

Page 117

background image

u

Navigating the Drive and Programming Modes

The drive is set to operate in Drive Mode when it is first powered up. Switch between display screens by using the

and

keys.

Mode

Contents

Operator Display

Description

Power Up

Frequency

Reference

(default)

- MODE -

U1-01= 0.00Hz
U1-02= 0.00Hz

U1-03= 0.00A

DRV

FREF (OPR)

Rdy

JOG

FWD

FWD/REV

LSEQ

LREF

This display screen allows the user to monitor and change the frequency reference while

the drive is running.

Refer to The Drive, Programming, and Clock Adjustment

Modes on page 114

.

Note:

The user can select the data displayed when the drive is first powered up

with parameter o1-02.

Drive Mode

Monitor Display

- MODE -

U1-01= 0.00Hz
U1-02= 0.00Hz

U1-03= 0.00A

DRV

Monitor Menu

Rdy

JOG

FWD

FWD/REV

LSEQ

LREF

Lists the monitor parameters (Uo-oo parameters) available in the drive.

Press the Enter Key and then use the Up, Down, ESC, and Reset keys to navigate through

the drive monitors.

Programming

Mode

Verify Menu

- MODE -

PRG

Modified Consts

HELP

DATA

FWD

Modified

X Parameters

Lists all parameters that have been edited or changed from default settings.

Refer to

Verifying Parameter Changes: Verify Menu on page 120

.

Setup Group

HELP

- MODE -

PRG

Quick Setting

DATA

FWD

A select list of parameters necessary to get the drive operating quickly.

Refer to

Using the Setup Groups on page 121

.

Note:

Parameters listed in the Setup Group differ depending the Application

Preset in parameter A1-06.

Refer to Application Selection on page 126

.

Parameter

Setting Mode

HELP

- MODE -

PRG

DATA

Programming

FWD

Allows the user to access and edit all parameter settings.

Refer to Parameter List on

page 413

.

Auto-Tuning

Mode

HELP

- MODE -

PRG Rdy

Auto-Tuning

DATA

AUTO

FWD

Motor parameters are calculated and set automatically.

Refer to Auto-Tuning on

page 129

.

Drive Mode

Frequency

Reference

- MODE -

U1-01= 0.00Hz
U1-02= 0.00Hz

U1-03= 0.00A

DRV

FREF (OPR)

Rdy

JOG

FWD

FWD/REV

LSEQ

LREF

Returns to the frequency reference display screen.

n

Drive Mode Details

The following actions are possible in the Drive Mode:
• Run and stop the drive
• Monitor the operation status of the drive (frequency reference, output frequency, output current, output voltage, etc.)
• View information on an alarm
• View a history of alarms that have occurred

4.3 The Drive, Programming, and Clock Adjustment Modes

YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual

117

4

Start-Up Programming & Operation

This manual is related to the following products: