beautypg.com

H: terminal functions, H1: multi-function digital inputs, 7 h: terminal functions – Yaskawa AC Drive-P1000 Industrial Fan User Manual

Page 204

background image

5.7 H: Terminal Functions

H parameters assign functions to the external terminals.

u

H1: Multi-Function Digital Inputs

n

H1-01 to H1-08: Functions for Terminals S1 to S8

These parameters assign functions to the multi-function digital inputs. The various functions and settings are listed in

Table

5.29

.

No.

Parameter Name

Setting

Range

Default

H1-01

Multi-Function Digital Input Terminal S1 Function Selection

1 to 9F

40 (F)

<1>

: Forward Run Command (2-Wire sequence)

H1-02

Multi-Function Digital Input Terminal S2 Function Selection

1 to 9F

41 (F)

<1>

: Reverse Run Command (2-Wire sequence)

H1-03

Multi-Function Digital Input Terminal S3 Function Selection

0 to 9F

24: External Fault

H1-04

Multi-Function Digital Input Terminal S4 Function Selection

0 to 9F

14: Fault Reset

H1-05

Multi-Function Digital Input Terminal S5 Function Selection

0 to 9F

3 (0)

<1>

: Multi-Step Speed Reference 1

H1-06

Multi-Function Digital Input Terminal S6 Function Selection

0 to 9F

4 (3)

<1>

: Multi-Step Speed Reference 2

H1-07

Multi-Function Digital Input Terminal S7 Function Selection

0 to 9F

6 (4)

<1>

: Jog Reference Selection

H1-08

Multi-Function Digital Input Terminal S8 Function Selection

0 to 9F

8: (6)

<1>

: External Baseblock Command

<1> Number appearing in parenthesis is the default value after performing a 3-Wire initialization (A1-03 = 3330).

Table 5.29 Multi-Function Digital Input Terminal Settings

Setting

Function

Page

0

3-Wire Sequence

205

1

LOCAL/REMOTE Selection

205

2

External Reference 1/2 Selection

206

3

Multi-Step Speed Reference 1

206

4

Multi-Step Speed Reference 2

5

Multi-Step Speed Reference 3

6

Jog reference Selection

206

7

Accel/Decel Time Selection 1

206

8

Baseblock Command (N.O.)

206

9

Baseblock Command (N.C.)

A

Accel/Decel Ramp Hold

206

B

Drive Overheat Alarm (oH2)

207

C

Analog Terminal Input Selection

207

F

Through Mode

207

10

Up Command

207

11

Down Command

12

Forward Jog

208

13

Reverse Jog

14

Fault Reset

208

15

Fast Stop (N.O.)

208

17

Fast Stop (N.C.)

208

18

Timer Function Input

209

19

PID Disable

209

1A

Accel/Decel Time Selection 2

209

1B

Program Lockout

209

1E

Reference Sample Hold

209

20 to 2F External Fault

210

30

PID Integral Reset

210

31

PID Integral Hold

210

Setting

Function

Page

32

Multi-Step Speed Reference 4

210

34

PID Soft Starter Cancel

210

35

PID Input Level Selection

210

40

Forward Run Command (2-Wire sequence)

211

41

Reverse Run Command (2-Wire sequence)

42

Run Command (2-Wire sequence 2)

211

43

FWD/REV Command (2-Wire sequence 2)

47

Node Setup

211

51

Disable Sequence Timers

211

52

Cancel Active Sequence Timer

211

60

DC Injection Braking Command

211

61

External Speed Search Command 1

211

62

External Speed Search Command 2

211

63

Field Weakening

212

65

KEB Ride-Thru 1 (N.C.)

212

66

KEB Ride-Thru 1 (N.O.)

67

Communications Test Mode

212

68

High Slip Braking (HSB)

212

6A

Drive Enabled

212

75

Up 2 Command

212

76

Down 2 Command

7A

KEB Ride-Thru 2 (N.C.)

213

7B

KEB Ride-Thru 2 (N.O.)

A8

Secondary PI Disable (N.O.)

213

A9

Secondary PI Disable (N.C.)

213

AA

Secondary PI Inverse Operation

213

AB

Secondary PI Integral Reset

213

AC

Secondary PI Integral Hold

213

AD

Select Secondary PI Parameters

214

5.7 H: Terminal Functions

204

YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual

This manual is related to the following products: