E.3 User Setting Table

Use the Verify Menu to determine which parameters have been changed from their original default settings

below the parameter number indicates that the parameter setting can be changed during run.

No.

Name

User

Setting

A1-00

Language Selection

A1-01

Access Level Selection

A1-03

Initialize Parameters

A1-04

Password

A1-05

Password Setting

A1-06

Application Preset

A2-01 to

A2-32

User Parameters, 1 to 32

A2-33

User Parameter Automatic Selection

b1-01

Frequency Reference Selection 1

b1-02

Run Command Selection 1

b1-03

Stopping Method Selection

b1-04

Reverse Operation Selection

b1-07

LOCAL/REMOTE Run Selection

b1-08

Run Command Selection while in Programming

Mode

b1-11

Run Delay Time Setting

b1-14

Phase Order Selection

b1-15

Frequency Reference Selection 2

b1-16

Run Command Selection 2

b1-17

Run Command at Power Up

b2-01

DC Injection Braking Start Frequency

b2-02

DC Injection Braking Current

b2-03

DC Injection Braking Time at Start

b2-04

DC Injection Braking Time at Stop

b3-01

Speed Search Selection at Start

b3-02

Speed Search Deactivation Current

b3-03

Speed Search Deceleration Time

b3-04

V/f Gain during Speed Search

b3-05

Speed Search Delay Time

b3-06

Output Current 1 during Speed Search

b3-07

Output Current 2 during Speed Search (Speed

Estimation Type)

b3-08

Current Control Gain during Speed Search (Speed

Estimation Type)

b3-10

Speed Search Detection Compensation Gain

b3-12

Minimum Current Detection Level during Speed

Search

b3-14

Bi-Directional Speed Search Selection

b3-17

Speed Search Restart Current Level

b3-18

Speed Search Restart Detection Time

b3-19

Number of Speed Search Restarts

b3-24

Speed Search Method Selection

b3-25

Speed Search Wait Time

No.

Name

User

Setting

b3-26

Direction Determining Level

b3-27

Start Speed Search Select

b4-01

Timer Function On-Delay Time

b4-02

Timer Function Off-Delay Time

b5-01

PID Function Setting

b5-02

Proportional Gain Setting (P)

b5-03

Integral Time Setting (I)

b5-04

Integral Limit Setting

b5-05

Derivative Time (D)

b5-06

PID Output Limit

b5-07

PID Offset Adjustment

b5-08

PID Primary Delay Time Constant

b5-09

PID Output Level Selection

b5-10

PID Output Gain Setting

b5-11

PID Output Reverse Selection

b5-12

PID Feedback Loss Detection Selection

b5-13

PID Feedback Loss Detection Level

b5-14

PID Feedback Loss Detection Time

b5-15

PID Sleep Function Start Level

b5-16

PID Sleep Delay Time

b5-17

PID Accel/Decel Time

b5-18

PID Setpoint Selection

b5-19

<1>

PID Setpoint Value

b5-20

PID Setpoint Scaling

b5-34

PID Output Lower Limit

b5-35

PID Input Limit

b5-36

PID Feedback High Detection Level

b5-37

PID Feedback High Detection Time

b5-38

PID Setpoint User Display

b5-39

PID Setpoint Display Digits

b5-40

Frequency Reference Monitor Content during PID

b5-41

PI Output 2 Unit Selection

b5-42

PI Output 2 Calculation Mode

E.3 User Setting Table

YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual

549

E