Fault Name

SEr

Too Many Speed Search Restarts
The number of Speed Search restarts exceeded the value set to b3-19.

Cause

Possible Solution

Parameters related to Speed Search are set to

the wrong values

• Reduce the detection compensation gain during Speed Search (b3-10).
• Increase the current level when attempting Speed Search (b3-17).
• Increase the detection time during Speed Search (b3-18).
• Repeat Auto-Tuning.

The motor is coasting in the opposite direction

of the Run command

Set b3-14 to 1 to enable Bi-Directional Speed Search.

Digital Operator Display

Fault Name

TdE

TdE

Time Data Error

Cause

Possible Solution

An error has occurred in the Real-Clock Time

function of the digital operator

Replace the digital operator. For instructions on replacing the digital operator, contact Yaskawa or your

nearest sales representative.

Digital Operator Display

Fault Name

<1>

THo

Thermistor Disconnect
The thermistor that detects motor temperature has become disconnected.

Cause

Possible Solution

The motor thermistor is not connected

properly.

Check the thermistor wiring.

<1> Detected in models 4A0930 and 4A1200.

Digital Operator Display

Fault Name

TIE

TIE

Time Interval Error

Cause

Possible Solution

An error has occurred in the Real-Clock Time

function of the digital operator

Replace the digital operator. For instructions on replacing the digital operator, contact Yaskawa or your

nearest sales representative.

Digital Operator Display

Fault Name

TIM

TIM

Time Not Set

Cause

Possible Solution

The Real-Time Clock for the digital operator

is not set in parameter o4-17
• The drive is a new drive, first power-up

condition

• o4-17 was set to 2, Reset, by the user,

manually clearing the Real-Time Clock

data.

Set o4-17 to 1 to set the time for the digital operator.

The drive will display the "TIM" alarm (Time Not Set) when the Real time Clock is not set . Additionally,

at power up, if the "TIM" condition is present, the drive will automatically switch to the time setting

screen (o4-17 = 1) for 30 seconds to prompt the user to set the Real-Time Clock.

The user did not set the Real Time Clock when

prompted following power-up.

Cycle power to the drive and set the Real Time Clock within 30 seconds of power-up, or set the clock

manually via parameter o4-17.

The digital operator battery is low or the

battery has been replaced

Replace the digital operator battery and set the Real-Time Clock.

An error has occurred in the Real-Time Clock

function of the digital operator

Replace the digital operator. For instructions on replacing the digital operator, contact Yaskawa or your

nearest sales representative.

Digital Operator Display

Fault Name

UL3

Undertorque Detection 1
The current has fallen below the minimum value set for torque detection (L6-02) for longer than the

allowable time (L6-03).

Cause

Possible Solution

Parameter settings are not appropriate for the

load

Check the settings of parameters L6-02 and L6-03.

There is a fault on the machine side

Check the load for any problems.