L1-04

Motor Overheat Fault Operation Selection (PTC input)

0 to 2

1

Setting 0: Ramp to Stop

The drive stops the motor using the deceleration time 1 set in parameter C1-02.

Setting 1: Coast to Stop

The drive output is switched off and the motor coasts to stop.

Setting 2: Fast Stop

The drive stops the motor using the Fast Stop time set in parameter C1-09.

n

L1-05: Motor Temperature Input Filter Time (PTC input)

Sets a filter on the PTC input signal to prevent erroneous detection of a motor overheat fault.

No.

Name

Setting Range

Default

L1-05

Motor Temperature Input Filter Time (PTC input)

0.00 to 10.00 s

0.20 s

n

L1-13: Continuous Electrothermal Operation Selection

Determines whether to hold the current value of the electrothermal motor protection (L1-01) when the power supply is

interrupted.

No.

Name

Setting Range

Default

L1-13

Continuous Electrothermal Operation Selection

0 to 2

1

Setting 0: Disabled
Setting 1: Enabled
Setting 2: Enabled (RTC)

n

Motor Protection Using an NTC Thermistor Input

Motor protection is possible for models 4A0930 and 4A1200 by connecting the NTC thermistor input in the motor windings

to one of the drive analog input terminals.
This enables the drive to provide torque compensation in response to changes in motor temperature and protect the motor from

overheating.
If the NTC input signal using the drive multi-function analog input terminal exceeds the overheat alarm level set to L1-16,

then “oH5” will flash on the digital operator screen. The drive will respond to the alarm according to the setting of L1-20

(default setting is to continue operation when an oH5 alarm occurs).

Figure 5.69

shows a circuit using the NTC thermistor and the terminal resistance values. Set jumper S1 on the drive to for

voltage input when wiring the NTC thermistor input to terminal A2 on the drive.

Note:

This example assumes that H3-10 = 17, H3-09 = 0, and that jumper S1 has been set for voltage input.

+V

(+10.5 V, 20 mA)

Voltage Divider
2 k

W

NTC Thermistor

A2 (0-10 V)

DIP Switch S1

AC

V

I

Drive

Figure 5.69 Motor Protection Circuit Using NTC Input

5.8 L: Protection Functions

YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual

237

5

Parameter Details