No.

(Addr.

Hex)

Name

Description

Values

Page

b2-04

(18C)

DC Injection Braking Time

at Stop

Sets DC Injection Braking time at stop.

Default: 0.50 s

Min.: 0.00

Max.: 10.00

153

u

b3: Speed Search

No.

(Addr

Hex.)

Name

Description

Values

Page

b3-01

(191)

Speed Search Selection at

Start

0: Disabled

1: Enabled

Default: 0

Range: 0, 1

156

b3-02

(192)

Speed Search Deactivation

Current

Sets the current level at which the speed is assumed to be detected and Speed

Search is ended. Set as a percentage of the drive rated current.

Default: 120%

Min.: 0

Max.: 200

156

b3-03

(193)

Speed Search Deceleration

Time

Sets output frequency reduction time during Speed Search.

Default: 2.0 s

Min.: 0.1

Max.: 10.0

156

b3-04

(194)

V/f Gain during Speed

Search

Determines how much to lower the V/f ratio during Speed Search.

Output voltage during Speed Search equals the V/f setting multiplied by b3-04.

Default:

<1>

Min.: 10%

Max.: 100%

157

b3-05

(195)

Speed Search Delay Time

When using an external contactor on the output side, b3-05 delays executing

Speed Search after a momentary power loss to allow time for the contactor to

close.

Default: 0.2 s

Min.: 0.0

Max.: 100.0

157

b3-06

(196)

Output Current 1 during

Speed Search

Sets the current injected to the motor at the beginning of Speed Estimation

Speed Search. Set as a coefficient for the motor rated current.

Default:

<1>

Min.: 0.0

Max.: 2.0

157

b3-07

(197)

Output Current 2 during

Speed Search (Speed

Estimation Type)

Sets the amount of output current during Speed Estimation Speed Search as a

coefficient for the no-load current.

Default:

<1>

Min.: 0.0

Max.: 5.0

157

b3-08

(198)

Current Control Gain during

Speed Search (Speed

Estimation Type)

Sets the proportional gain for the current controller during Speed Search.

Default: 0.8

Min.: 0.00

Max.: 6.00

157

b3-10

(19A)

Speed Search Detection

Compensation Gain

Sets the gain which is applied to the speed detected by Speed Estimation Speed

Search before the motor is reaccelerated. Increase this setting if ov occurs

when performing Speed Search after a relatively long period of baseblock.

Default: 1.05

Min.: 1.00

Max.: 1.20

157

b3-12

(19C)

Minimum Current Detection

Level during Speed Search

Sets the minimum current detection level during Speed Search.

Default: 6.0

Min.: 2.0

Max.: 10.0

157

b3-14

(19E)

Bi-Directional Speed Search

Selection

0: Disabled (uses the direction of the frequency reference)

1: Enabled (drive detects which way the motor is rotating)

Default: 1

Range: 0, 1

157

b3-17

(1F0)

Speed Search Restart

Current Level

Sets the Speed Search restart current level as a percentage of the drive rated

current.

Default: 150%

Min.: 0

Max.: 200

158

b3-18

(1F1)

Speed Search Restart

Detection Time

Sets the time to detect Speed Search restart.

Default: 0.10 s

Min.: 0.00

Max.: 1.00

158

b3-19

(1F2)

Number of Speed Search

Restarts

Sets the number of times the drive can attempt to restart when performing

Speed Search.

Default: 3

Min.: 0

Max.: 10

158

b3-24

(1C0)

Speed Search Method

Selection

0: Current Detection

1: Speed Estimation

Default: 0

Range: 0, 1

158

b3-25

(1C8)

Speed Search Wait Time

Sets the time the drive must wait between each Speed Search restart attempt. Default: 0.5 s

Min.: 0.0

Max.: 30.0

158

b3-26

(1C7)

Direction Determining

Level

Sets the level that determines the direction of motor rotation.

Default:

<1>

Min.: 40

Max.: 60000

158

b3-27

(1C9)

Start Speed Search Select

Selects a condition to activate Speed Search Selection at Start (b3-01) or

External Speed Search Command 1 or 2 from the multi-function input.

0: Triggered when a Run command is issued (normal).

1: Triggered when an external baseblock is released.

Default: 0

Range: 0, 1

159

<1> Default setting is dependent on parameter o2-04, Drive Model Selection.

B.3 b: Application

YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual

417

B

Parameter List

This manual is related to the following products: