Contents

00C2H

Fault Contents 5
bit 0

MEMOBUS/Modbus Communication Error (CE)

bit 1

Option Communication Error (bUS)

bit 2 to 5

Reserved

bit 6

Option External Fault (EF0)

bit 7

PID Feedback Loss (FbL)

bit 8

Undertorque Detection 1 (UL3)

bit 9

Undertorque Detection 2 (UL4)

bit A

High Slip Braking Overload (oL7)

bit B to E

Reserved

bit F

Hardware Fault (includes oFx)

00C3H

Fault Contents 6
bit 0 to 4

Reserved

bit 5

Current Imbalance (LF2)

bit 6

Pullout Detection (STo)

bit 7

Reserved

bit 8

SI-T3 Watchdog Error (E5)

bit 9

Reserved

bit A

Too many speed search restarts (SEr)

bit B to F

Reserved

00C4H

Fault Contents 7
bit 0

PID Feedback Loss (FbH)

bit 1

External Fault 1, input terminal S1 (EF1)

bit 2

External Fault 2, input terminal S2 (EF2)

bit 3, 4

Reserved

bit 5

Current Offset Fault (CoF)

bit 6 to B

Reserved

bit C

Output Voltage Detection Fault (voF)

bit D

Braking Resistor Fault (rF)

bit E

Braking Transistor Overload Fault (boL)

bit F

Motor Overheat (NTC Input) (oH5)

00C5H

Fault Contents 8

bit 0

Reserved

bit 1

Node Setup Fault (nSE)

bit 2

Thermistor Disconnect (THo)

bit 3

Variable Torque Overload (VToL)

bit 4 to 8

Reserved

bit 9

Underload Detection 6 (UL6)

bit A, B

Reserved

bit C

HOA Time Not Set (TIM)

bit D

HOA Battery Low (bAT)

bit E

HOA Time Data Error (TdE)

bit F

HOA Time Interval Error (TIE)

00C6H to 00C7H

Reserved

C.9 MEMOBUS/Modbus Data Table