Yaskawa AC Drive-P1000 Industrial Fan User Manual
Page 504

Register No.
Contents
00C2H
Fault Contents 5
bit 0
MEMOBUS/Modbus Communication Error (CE)
bit 1
Option Communication Error (bUS)
bit 2 to 5
Reserved
bit 6
Option External Fault (EF0)
bit 7
PID Feedback Loss (FbL)
bit 8
Undertorque Detection 1 (UL3)
bit 9
Undertorque Detection 2 (UL4)
bit A
High Slip Braking Overload (oL7)
bit B to E
Reserved
bit F
Hardware Fault (includes oFx)
00C3H
Fault Contents 6
bit 0 to 4
Reserved
bit 5
Current Imbalance (LF2)
bit 6
Pullout Detection (STo)
bit 7
Reserved
bit 8
SI-T3 Watchdog Error (E5)
bit 9
Reserved
bit A
Too many speed search restarts (SEr)
bit B to F
Reserved
00C4H
Fault Contents 7
bit 0
PID Feedback Loss (FbH)
bit 1
External Fault 1, input terminal S1 (EF1)
bit 2
External Fault 2, input terminal S2 (EF2)
bit 3, 4
Reserved
bit 5
Current Offset Fault (CoF)
bit 6 to B
Reserved
bit C
Output Voltage Detection Fault (voF)
bit D
Braking Resistor Fault (rF)
bit E
Braking Transistor Overload Fault (boL)
bit F
Motor Overheat (NTC Input) (oH5)
00C5H
Fault Contents 8
bit 0
Reserved
bit 1
Node Setup Fault (nSE)
bit 2
Thermistor Disconnect (THo)
bit 3
Variable Torque Overload (VToL)
bit 4 to 8
Reserved
bit 9
Underload Detection 6 (UL6)
bit A, B
Reserved
bit C
HOA Time Not Set (TIM)
bit D
HOA Battery Low (bAT)
bit E
HOA Time Data Error (TdE)
bit F
HOA Time Interval Error (TIE)
00C6H to 00C7H
Reserved
C.9 MEMOBUS/Modbus Data Table
504