B.15 defaults by drive model – Yaskawa AC Drive-P1000 Industrial Fan User Manual

Page 477

background image

No.

Name

Unit

Default Settings

Model CIMR-Po

4A0675

4A0930

4A1200

o2-04

Drive Model Selection

Hex.

AE

B0

B2

E2-11

Motor rated power

kW (HP)

355

(500

-550)

500

(750)

630

(1000)

b3-04

V/f Gain during Speed Search

%

60

60

60

b3-06

Output Current 1 during Speed Search

0.7

0.7

0.7

b3-07

Output Current 2 during Speed Search

(Speed Estimation Type)

2.0

2.0

b3-26

Start Speed Search Select

1000

1000

b8-03

Energy Saving Control Filter Time Constant

s

2.00

2.00

2.00

b8-04

Energy Saving Coefficient Value

23.84

20.26

17.06

C5-17

Motor Inertia

kgm

2

12.00

14.00

18.00

C6-02

Carrier Frequency Selection

7

7

7

E2-01

Motor Rated Current

A

650

900

1200

E2-02

Motor Rated Slip

Hz

1

0.9

0.7

E2-03

Motor No-Load Current

A

130

180

240

E2-05

Motor Line-to-Line Resistance

Ω

0.012

0.009

0.006

E2-06

Motor Leakage Inductance

%

20

20

20

E2-10

Motor Iron Loss for Torque Compensation

W

5560

7833

11123

L2-02

Momentary Power Loss Ride-Thru Time

s

2

2

2

L2-03

Momentary Power Loss Min. Basebl. Time

s

2.3

3.1

4.6

L2-04

Momentary Power Loss Volt. Recov. Time

s

1

3

4.5

L3-24

Motor Acceleration Time for Inertia Calculations

s

1.667

2.222

3.333

L8-02

Overheat Alarm Level

°C

140

140

140

L8-35

Installation Method Selection

0

0

0

L8-38

Carrier Frequency Reduction Selection

2

2

2

n1-03

Hunting Prevention Time Constant

ms

100

100

100

Table B.8 600 V Class Drives Default Settings by Drive Model

No.

Name

Unit

Model CIMR-Po

5A0003

5A0004

5A0006

5A0009

5A0011

o2-04

Drive Model Selection

Hex.

C3

C4

C5

C7

E2-11

Motor Rated Power

kW

(HP)

1.5

(2)

2.2

(3)

3.7

(5)

5.5

(7.5)

7.5

(10)

b3-04

V/f Gain during Speed Search

%

100

100

100

100

100

b3-06

Output Current 1 during Speed Search

0.5

0.5

0.5

0.5

0.5

b3-07

Output Current 2 during Speed Search

(Speed Estimation Type)

b3-26

Start Speed Search Select

b8-03

Energy Saving Control Filter Time Constant

s

0.50

0.50

0.50

0.50

0.50

b8-04

Energy Saving Coefficient Value

494.4

415.3

320.2

239.95

199.86

C5-17

Motor Inertia

kgm

2

0.0068

0.0088

0.0158

0.0255

0.037

C6-02

Carrier Frequency Selection

7

7

7

7

7

E2-01

Motor Rated Current

A

2.7

3.9

6.1

9

11

E2-02

Motor Rated Slip

Hz

2.5

3.0

2.7

1.5

1.3

E2-03

Motor No-Load Current

A

0.8

1.2

1.8

2.7

3.3

E2-05

Motor Line-to-Line Resistance

Ω

13.72

8.825

4.936

2.601

1.446

E2-06

Motor Leakage Inductance

%

18.3

18.7

19.3

18.2

15.5

E2-10

Motor Iron Loss for Torque Compensation

W

53

77

130

193

263

L2-02

Momentary Power Loss Ride-Thru Time

s

0.2

0.3

0.5

0.5

0.8

L2-03

Momentary Power Loss Minimum Baseblock

Time

s

0.5

0.5

0.8

0.8

1

B.15 Defaults by Drive Model

YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual

477

B

Parameter List