For a list of alarm codes, Minor faults and alarms – Yaskawa AC Drive-P1000 Industrial Fan User Manual
Page 294

Digital
Operator
Display
Name
Page
SEr
Too Many Speed Search Restarts
TdE
Time Data Error
THo
<4>
Thermistor Disconnect
TIE
Time Interval Error
TIM
Time Not Set
UL3
Undertorque Detection 1
UL4
Undertorque Detection 2
UL6
Motor Underload
UnbC
<4>
Current Unbalance
Digital
Operator
Display
Name
Page
Uv1
<3>
Undervoltage
Uv2
<3>
Control Power Supply Undervoltage
Uv3
<3>
Soft Charge Circuit Fault
Uv4
<4>
Gate Drive Board Undervoltage
voF
Output Voltage Detection Fault
vToL
VT Overload
<1> Displayed as CPF00 when occurring at drive power up. When one of the faults occurs after successfully starting the drive, the display will show
CPF01.
<2> Displayed as CPF20 when occurring at drive power up. When one of the faults occurs after successfully starting the drive, the display will show
CPF21.
<3> Fault histories are not kept when CPF00, CPF01, CPF06, CPF24, oFA00, oFb00, oFC00, Uv1, Uv2, or Uv3 occur.
<4> Detected in models 4A0930 and 4A1200.
n
Minor Faults and Alarms
important to distinguish between faults and alarms to determine the proper corrective actions.
When the drive detects an alarm, the ALM indicator LED blinks and the alarm code display flashes. Most alarms trigger a
digital output programmed for alarm output (H2-oo = 10). A fault (not an alarm) is present if the ALM LED lights without
blinking.
for information on fault codes.
Table 6.5 Minor Fault and Alarm Displays
Digital
Operator
Display
Name
Minor Fault
Output
(H2-oo = 10)
Page
AEr
SI-T Station Number Setting Error
(CC-Link, CANopen,
MECHATROLINK-II)
YES
bAT
HOA Keypad Battery Voltage Low
YES
bb
Drive Baseblock
No output
boL
Braking Transistor Overload Fault
YES
bUS
Option Card Communications
Error
YES
CALL
Serial Communication
Transmission Error
YES
CE
MEMOBUS/Modbus
Communication Error
YES
CrST
Cannot Reset
YES
dnE
Drive Disabled
YES
E5
SI-T3 Watchdog Timer Error
YES
EoF
Emergency Override Forward Run
YES
Eor
Emergency Override Reverse Run
YES
EF
Run Command Input Error
YES
EF0
Option Card External Fault
YES
EF1 to EF8 External Fault
(input terminal S1 to S8)
YES
FbH
Excessive PID Feedback
YES
FbL
PID Feedback Loss
YES
HCA
Current Alarm
YES
Digital
Operator
Display
Name
Minor Fault
Output
(H2-oo = 10)
Page
LT-1
Cooling Fan Maintenance Time
No output
<1>
LT-2
Capacitor Maintenance Time
No output
<1>
LT-3
Soft Charge Bypass Relay
Maintenance Time
No output
<1>
LT-4
IGBT Maintenance Time (50%)
No output
<1>
oH
Heatsink Overheat
YES
oH2
Drive Overheat
YES
oH3
Motor Overheat
YES
oH5
<2>
Motor Overheat
YES
ov
Overvoltage
YES
PASS
MEMOBUS/Modbus Test Mode
Complete
No output
rUn
During Run 2, Motor Switch
Command Input
YES
SE
MEMOBUS/Modbus Test Mode
Fault
YES
TdE
Time Data Error
YES
THo
<2>
Thermistor Disconnect
YES
TIE
Time Interval Error
YES
TrPC
IGBT Maintenance Time (90%)
YES
6.3 Drive Alarms, Faults, and Errors
294
YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual