Three-Phase 400 V Class Drive Models 4A0208 to 4A1200
Table A.6 Power Ratings Continued (Three-Phase 400 V Class)
Item
Specification
Drive Models
4A0208 4A0250 4A0296 4A0362 4A0414 4A0515 4A0675 4A0930 4A1200
Maximum Applicable Motor
Capacity (HP)
<1>
ND Rating
150
200
250
300
350
400-450 500-550
750
1000
HD Rating
125-150
150
200
250
300
350
400-450-
500
650
900
Input
Input Current (A)
<2>
ND Rating
207
248
300
346
410
465
657
922
1158
HD Rating
170
207
248
300
346
410
584
830
1031
Rated Voltage
Rated Frequency
Three-phase: 380 to 480 Vac 50/60 Hz/510 to 680 Vdc
<3>
Allowable Voltage Fluctuation
-15 to 10%
Allowable Frequency Fluctuation
±5%
Input Power (kVA)
ND Rating
189
227
274
316
375
425
601
843
1059
HD Rating
155
189
227
274
316
375
534
759
943
Output
Rated Output Capacity
(kVA)
<4>
ND Rating
<5>
189
227
274
316
375
425
601
843
1059
HD Rating
137
<6>
165
<6>
198
<6>
232
<6>
282
<6>
343
<5>
461
<5>
617
<5>
831
<5>
Rated Output Current
(A)
ND Rating
<5>
208
250
296
362
414
515
675
930
1200
HD Rating
180
<6>
216
<6>
260
<6>
304
<6>
370
<7>
450
<5>
605
<5>
810
<5>
1090
<5>
Overload Tolerance
ND Rating: 120% of rated output current for 60 s
HD Rating: 150% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
Carrier Frequency
User-adjustable between 1 and 10 kHz
User-adjustable between 1 and 5 kHz
Maximum Output Voltage (V)
Three-phase: 380 to 480 Vac (proportional to input voltage)
0.95 ×
[input voltage]
Maximum Output Frequency (Hz)
400 Hz (user-adjustable)
<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than
the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.
<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring conditions,
and power supply impedance.
<3> DC input is not available for UL standards.
<4> Rated motor capacity is calculated with a rated output voltage of 440 V.
<5> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.
<6> Carrier frequency can be increased to 5 kHz while keeping this current derating. Higher carrier frequency settings require derating.
<7> Carrier frequency can be increased to 5 kHz while keeping this current derating. Higher carrier frequency settings require derating.
A.1 Power Ratings
YASKAWA SIEP YAIP1U 01B AC Drive - P1000 Technical Manual
401
A
Specifications