No.
(Addr.
Hex)
Name
Description
Values
Page
F7-22
(3FA)
EtherNet/IP Time Scaling
Sets the scaling factor for the time monitor in EtherNet/IP Class ID 2AH
Object.
Default: 0
Min.: -15
Max.: 15
–
F7-23 to
F7-32
(3FB to
374)
Dynamic Output Assembly
Parameters
Parameters used in Output Assembly 116. Each parameter contains a
MEMOBUS/Modbus address. The value received for Output Assembly 116
will be written to this corresponding MEMOBUS/Modbus address. A
MEMOBUS/Modbus address value of 0 means that the value received for
Output Assembly 116 will not be written to any MEMOBUS/Modbus register.
Default: 0
–
F7-33 to
F7-42
(375 to
37E)
Dynamic Input Assembly
Parameters
Parameters used in Input Assembly 166. Each parameter contains a
MEMOBUS/Modbus address. The value sent for Input Assembly 166 will be
read from this corresponding MEMOBUS/Modbus address. A MEMOBUS/
Modbus address value of 0 means that the value sent for Input Assembly 166
is not defined by the user, therefore the option default register value will be
returned.
Default: 0
–
<1> Parameter setting value is not reset to the default value when the drive is initialized.
<2> Cycle power for setting changes to take effect.
<3> If F7-13 is set to 0, all IP addresses (F7-01 to F7-04) must be unique.